Ubiquiti TOUGHSwitch PoE [21/43] Firmware update
![Ubiquiti TOUGHSwitch PoE [21/43] Firmware update](/views2/1072914/page21/bg15.png)
18
Chapter 5: Device Tab TOUGHSwitch
™
PoE User Guide
Ubiquiti Networks, Inc.
Total Throughput for TX and RX are also displayed.
Place your mouse over a port to view its PoE status,
Speed setting, duplex mode, and statistics for TX and RX
throughput.
Revert Changes To cancel your changes, click Revert
Changes.
Test Changes To try the changes without saving them,
click Test Changes. To keep the changes, click Apply. If
you do not click Apply within 180 seconds (the countdown
is displayed), the device times out and resumes its earlier
configuration.
Save Changes To immediately save your changes, click
Save Changes.
Firmware Update
This section manages the firmware maintenance.
Firmware Version Displays the current firmware version.
Build Number Displays the build number of the firmware
version.
Check for Updates By default, the firmware automatically
checks for updates. To manually check for an update, click
Check Now.
Update Firmware The TOUGHSwitch firmware update
is compatible with all configuration settings. The system
configuration is preserved while the TOUGHSwitch is
updated with a new firmware version. However, we
recommend that you click Download in the Configuration
Management section to back up your current system
configuration before updating the firmware.
Updating the firmware is a three-step procedure:
1. Click Choose File to locate the new firmware file. Select
the file and click Open.
2. Click Upload to upload the new firmware to the
TOUGHSwitch.
3. The Uploaded Firmware Version is displayed. Click
Update to confirm.
If the firmware update is in process, you can close the
firmware update window, but this does not cancel the
firmware update. Please be patient, as the firmware
update routine can take three to seven minutes. You
cannot access the TOUGHSwitch until the firmware update
routine is completed.
WARNING: Do not power off, do not reboot, and do
not disconnect the TOUGHSwitch from the power
supply during the firmware update process as
these actions will damage the TOUGHSwitch!
Management Network Settings
The Management Network Settings configure the IP
settings and management access of the TOUGHSwitch.
Because the TOUGHSwitch is a Layer 2 device, the IP
Address and Netmask are not mandatory; however, if you
want to manage the TOUGHSwitch, then you will need to
configure the IP Address and Netmask unless you select
DHCP.
Management IP Address The TOUGHSwitch can use a
static IP address or obtain an IP address from its DHCP
server.
• Static Assign static IP settings to the TOUGHSwitch.
Note: IP settings should be consistent with the
address space of the TOUGHSwitch’s network
segment.
- IP Address Specify the IP address of the
TOUGHSwitch. This IP will be used for device
management purposes. The default is 192.168.1.20.
- Netmask When the netmask is expanded into its
binary form, it provides a mapping to define which
portions of the IP address range are used for the
network devices and which portions are used for host
devices. The netmask defines the address space of
the TOUGHSwitch’s network segment. The default
255.255.255.0 (or “/24”) netmask is commonly used on
many Class C IP networks.
- Management Port Only By default, this option is
disabled and you can manage the TOUGHSwitch
through any port. To restrict management access to
only the Management port, check this box.
Note: The Management Port Only option must be
disabled if you want traffic to flow between the
Management port and numbered ports. Traffic
will be limited to 10/100 Mbps and, under heavy
load, may cause performance degradation of the
TOUGHSwitch.
- Gateway IP Typically, this is the IP address of the host
router, which provides the point of connection to the
Internet. This can be a DSL modem, cable modem,
or WISP gateway router. The TOUGHSwitch directs
packets to the gateway if the destination host is not
within the local network. The default is 192.168.1.1.
- Primary DNS IP Specify the IP address of the primary
DNS (Domain Name System) server.
Содержание
- Chapter 1 2
- Chapter 2 2
- Chapter 3 2
- Chapter 4 2
- Chapter 5 2
- Device tab 2
- Installation 2
- Navigation 2
- Overview 2
- Status tab 2
- Table of contents 2
- Alerts tab 3
- Appendix a 3
- Appendix b 3
- Appendix c 3
- Appendix d 3
- Appendix e 3
- Appendix f 3
- Chapter 6 3
- Chapter 7 3
- Chapter 8 3
- Chapter 9 3
- Compliance information 3
- Contact information 3
- Declaration of conformity 3
- Ports tab 3
- Safety notices 3
- Specifications 3
- Vlans tab 3
- Warranty 3
- Chapter 1 overview 4
- Configuration interface system requirements 4
- Hardware overview 4
- Introduction 4
- Package contents 4
- Toughswitch poe 4
- Toughswitch poe carrier 4
- Toughswitch poe pro 4
- Back panel 5
- Chapter 1 overview toughswitc 5
- Front panel leds 5
- Front panel ports 5
- Poe user guide 5
- Toughswitch poe 5
- Ubiquiti networks inc 5
- Chapter 1 overview toughswitc 6
- Front panel leds 6
- Front panel ports 6
- Note there are additional ventilation holes on the top and sides of the toughswitch 6
- Poe user guide 6
- Toughswitch poe pro back panel 6
- Ubiquiti networks inc 6
- A and b designate the two 8 port toughswitch poe pros housed in the rack this may be useful for the location setting on the device tab in the configuration interface 7
- Back panel 7
- Chapter 1 overview toughswitc 7
- Front panel ports 7
- Note there are additional ventilation holes on the top and sides of the toughswitch 7
- Poe user guide 7
- Toughswitch poe carrier 7
- Ubiquiti networks inc 7
- Chapter 1 overview toughswitc 8
- Front panel leds 8
- Poe user guide 8
- Ubiquiti networks inc 8
- Chapter 2 installation 9
- Configuration 9
- Grounding the toughswitch optional 9
- Installation of the toughswitch poe 9
- Installation requirements 9
- Introduction 9
- Wall mounting optional 9
- Connecting ethernet 10
- Connecting power 10
- Connecting ethernet 11
- Connecting power 11
- Installation of the toughswitch poe pro 11
- Installation requirements 11
- Hardware installation 12
- Installation of the toughswitch poe carrier 12
- Installation requirements 12
- Connecting ethernet 13
- Daisy chain option 13
- Uplink options 13
- Uplink to core switch option 13
- Accessing the configuration interface 14
- Chapter 3 navigation 14
- Configuring the toughswitch poe carrier 15
- Interface tabs 15
- Product verification 15
- Chapter 4 status tab 16
- Port statistics 17
- Port status 17
- Status 17
- Data distribution 18
- Details for port 18
- Packet distribution 18
- Total throughput 18
- Packet rate 19
- Throughput 19
- Chapter 5 device tab 20
- Firmware update 21
- Management network settings 21
- Basic settings 22
- Management connection settings 22
- Ssh server 22
- Web server 22
- Dynamic dns 23
- Services 23
- Snmp agent 23
- Telnet server 23
- Jumbo frames 24
- Ntp client 24
- Spanning tree protocol 24
- System log 24
- Configuration management 25
- Device discovery 25
- Device maintenance 25
- System accounts 25
- Chapter 6 ports tab 26
- Basic settings for port 27
- Ping watchdog for port 27
- Configure alerts for port 28
- Spanning tree settings for port 28
- Chapter 7 vlans tab 29
- Alert log 31
- Chapter 8 alerts tab 31
- System log 32
- Chapter 9 tools 33
- Mac forwarding table 33
- Mac table 33
- Discovery 34
- Network ping 34
- Traceroute 34
- Appendix a specifications 35
- Appendix a specifications toughswitc 35
- Poe user guide 35
- Ubiquiti networks inc 35
- Appendix a specifications toughswitc 36
- Poe user guide 36
- Ubiquiti networks inc 36
- Appendix b safety notices 37
- Electrical safety information 37
- Appendix c warranty 38
- Disclaimer 38
- Limitation of liability 38
- Limited warranty 38
- Returns 38
- Warranty conditions 38
- Appendix d compliance information 40
- Australia and new zealand 40
- Ce marking 40
- Deutsch 40
- English 40
- Industry canada 40
- Rohs weee compliance statement 40
- Español 41
- Français 41
- Italiano 41
- Appendix e declaration of conformity 42
- Appendix e declaration of conformity toughswitc 42
- Dansk danish 42
- Deutsch german 42
- Eesti estonian 42
- English 42
- Español spanish 42
- Français french 42
- Italiano italian 42
- Latviski latvian 42
- Lietuviškai lithuanian 42
- Magyar hungarian 42
- Malti maltese 42
- Nederlands dutch 42
- Norsk norwegian 42
- Poe user guide 42
- Polski polish 42
- Português portuguese 42
- Română romanian 42
- Slovensky slovak 42
- Suomi finnish 42
- Svenska swedish 42
- Ubiquiti networks inc 42
- Íslenska icelandic 42
- Česky czech 42
- Ελληνική greek 42
- Appendix f contact information 43
- Online resources 43
- Ubiquiti networks support 43
Похожие устройства
- Buderus LOGAMAX PLUS GB022 Инструкция по эксплуатации
- Tefal D2300512 Инструкция по эксплуатации
- Ubiquiti TOUGHSwitch PoE PRO Инструкция по эксплуатации
- Buderus LOGAMAX U022-24K Инструкция по эксплуатации
- Ubiquiti TOUGHSwitch PoE CARRIER Инструкция по эксплуатации
- Buderus LOGAMAX U024-24K Инструкция по эксплуатации
- Ubiquiti RB2011UiAS-2HnD-IN Инструкция по эксплуатации
- Buderus LOGANO G211 Инструкция по эксплуатации
- Ubiquiti RB951-2n Инструкция по эксплуатации
- Buderus LOGANO G115 WS Инструкция по эксплуатации
- Tefal D8210412 Инструкция по эксплуатации
- Ubiquiti RB951Ui-2HnD Инструкция по эксплуатации
- Buderus LOGANO SK425 Инструкция по эксплуатации
- Buderus LOGANO SE 425 Инструкция по эксплуатации
- Ubiquiti RB751G-2HnD Инструкция по эксплуатации
- Buderus LOGANO SK625 Инструкция по эксплуатации
- Ubiquiti RB951G-2HnD Инструкция по эксплуатации
- Tefal D8210512 Инструкция по эксплуатации
- Buderus LOGANO SK725 Инструкция по эксплуатации
- Ubiquiti RB2011iL-IN Инструкция по эксплуатации
Скачать
Случайные обсуждения