Daikin RXS50BVMB [119/178] Hall ic check

Daikin RXS50BVMB [119/178] Hall ic check
Check SiBE05-312
110 Service Diagnosis
5.1.13 Hall IC Check
Check No.16 1. Check the connector connection.
2. With the power ON, operation OFF, and the connector connected, check the following.
*Output voltage of about 5 V between pins 1 and 3.
*Generation of 3 pulses between pins 2 and 3 when the fan motor is operating.
Failure of (1)
faulty PCB
Replace the PCB.
Failure of (2)
faulty hall IC
Replace the fan motor.
Both (1) and (2) result
Replace the PCB.