Daikin FLY22GAV1NB [12/13] Trial operation and testing
Содержание
- Daikin 1
- Installation manual 1
- Split series 1
- Daikin 3
- Daikin industries ltd 3
- Electromagnetic compatibility 89 336 eec 3
- En60335 2 40 3
- Fl25gav1nb fl35gav1nb fl40gav1nb fl45gav1nb fly22gav1nb fly35gav1nb fly40gav1nb fly45gav1nb 3
- Hitoshi jinn manager quality control department shiga 1st of december 2000 3
- Low voltage 73 23 eec 3
- Machinery safety 89 392 eec 3
- Umeda center bldg 4 12 nakazaki nishi 2 chome kita ku osaka 530 8323 japan 3
- Safety precautions 4
- Before installing the indoor unit 5
- Ccessories 5
- Choosing a site 5
- Installation tips 5
- Drawings 6
- Indoor unit installation 6
- Drawings 7
- Indoor unit installation 7
- Zzzz zz 7
- Ceiling mounting 8
- Indoor unit 8
- Indoor unit 9
- Installation 9
- Installing indoor unit 9
- Wall mounting 9
- Commonality between ceiling mounting and wall mounting 10
- Indoor unit 10
- Indoor unit 11
- Purging air and checking gas leakage 12
- Test items 12
- Trial operation and testing 12
- Daikin europe nm 13
- Daikin industries ltd 13
- English 2p060565 5a m00b058 13
Похожие устройства
- Daikin FLY22GAV1NB Инструкция по эксплуатации
- Daikin FLY35GAV1NB Технические данные
- Daikin FLY35GAV1NB Инструкция по монтажу
- Daikin FLY35GAV1NB Инструкция по эксплуатации
- Daikin FLY40GAV1NB Технические данные
- Daikin FLY40GAV1NB Инструкция по эксплуатации
- Daikin FLY40GAV1NB Инструкция по монтажу
- Daikin FLY45GAV1NB Технические данные
- Daikin FLY45GAV1NB Инструкция по монтажу
- Daikin FLY45GAV1NB Инструкция по эксплуатации
- Daikin FLY22GV1NB Инструкция по монтажу
- Daikin FLY22GV1NB Инструкция по эксплуатации
- Daikin FLY22GV1NB Сервис мануал
- Daikin FLY35GV1NB Инструкция по монтажу
- Daikin FLY35GV1NB Инструкция по эксплуатации
- Daikin FLY35GV1NB Сервис мануал
- Daikin FLY40GV1NB Инструкция по монтажу
- Daikin FLY40GV1NB Инструкция по эксплуатации
- Daikin FLY40GV1NB Сервис мануал
- Daikin FLY45GV1NB Инструкция по монтажу
PURGING AIR AND CHECKING GAS LEAKAGE REFER TO THE INSTALLATION MANUAL OF THE OUTDOOR UNIT TRIAL OPERATION AND TESTING Trial Operation and Testing 1 Measure the supply voltage and make sure that it falls in the specified range 2 Trial operation should be carried out in cooling mode Select the lowest programmable temperature Trial operation in cooling mode may be disabled depending on the room temperature Use the remote control for trial operation as described below Trial operation from Remote Controller 1 Press ON OFF button to turn on the system 2 Simultaneously press DOWN UP and MODE buttons 3 Press MODE button twice T will appear on the display to indicate that Trial Operation mode is selected 4 Trial run mode terminates in approx 30 minutes and switches into normal mode To quit a trial operation press ON OFF button After trial operation is complete set the temperature to a normal level 26 C to 28 C For protection the unit disables restart operation for 3 minutes after it is turned off 3 Carry out the test operation in accordance with the Operation Manual to ensure that all functions and parts such as louver movement are working properly The air conditioner requires a small amount of power in its standby mode If the system is not to be used for some time after installation shut off the circuit breaker to eliminate unnecessary power consumption If the circuit breaker trips to shut off the power to the air conditioner the system will restore the original operation mode when the circuit breaker is opened again Test Items Test Items 9 Symptom diagnostic display on RC Indoor and outdoor units are installed properly on solid bases Fall vibration noise No refrigerant gas leaks Incomplete cooling function Refrigerant gas and liquid pipes and indoor drain hose extension are thermally insulated Water leakage Draining line is properly installed Water leakage System is properly earthed Electrical leakage The specified wires are used for interconnecting wire connections Inoperative or burn damage U4 Indoor or outdoor unit s air intake or exhaust has clear path of air Shut off valves are opened Incomplete cooling function E5 Indoor unit properly receives remote control commands Inoperative Check