SAFETY PRECAUTIONS REFER TO THE INSTALLATION MANUAL OFTHE OUTDOOR UNIT FOR THE ITEMS NOT DESCRIBED BELOW Read these SAFETY PRECAUTIONS carefully to ensure correct installation This manual classifies the precautions into WARNINGS and CAUTIONS Be sure to follow all the precautions below they are all important for ensuring safety A WARNINGS Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury A CAUTIONS Failure to follow any of CAUTION may in some cases result in grave consequences The following safety symbols are used throughout this manual Q Be sure to observe this instruction Be sure to establish an earth connection Never attempt After completing installation test the unit to check for installation errors Give the user adequate instructions concerning the use and cleaning of the unit according to the Operation Manual A WARNINGS Installation should be left to the dealer or another professional Improper installation may cause water leakage electrical shock or fire Install the air conditioner according to the instructions given in this manual Incomplete installation may cause water leakage electrical shock or fire Be sure to use the supplied or specified installation parts Use of other parts may cause the unit to come to lose water leakage electrical shock or fire Install the air conditioner on a solid base that can support the unit s weight An inadequate base or incomplete installation may cause injury in the event the unit falls off the base Electrical work should be carried out in accordance with the installation manual and the national electrical wiring rules or code of practice Insufficient capacity or incomplete electrical work may cause electrical shock or fire Be sure to use a dedicated power circuit Never use a power supply shared by another appliance For wiring use a cable long enough to cover the entire distance with no connection Do not use an extension cord Do not put other loads on the power supply use a dedicated power circuit Failure to do so may cause abnormal heat electric shock or fire Use the specified types of wires for electrical connections between the indoor and outdoor units Firmly clamp the interconnecting wires so their terminals receive no external stresses Incomplete connections or clamping may cause terminal overheating or fire After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue force on the electrical covers or panels Install covers over the wires Incomplete cover installation may cause terminal overheating electrical shock or fire If any refrigerant has leaked out during the installation work ventilate the room The refrigerant produces a toxic gas if exposed to flames After all installation is complete check to make sure that no refrigerant is leaking out The refrigerant produces a toxic gas if exposed to flames When installing or relocating the system be sure to keep the refrigerant circuit free from substances other than the specified refrigerant R22 such as air Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture resulting in injury _____________________________________________________________________ Be sure to establish an earth Do not earth the unit to a utility pipe arrester or telephone earth Incomplete earth may cause electrical shock A high surge current from lightning or other sources may cause damage to the air conditioner An earth leakage circuit breaker may be required depending on site condition to prevent electrical shock Failure to do so may cause electrical shock A CAUTIONS Do not install the air conditioner in a place where there is danger of exposure to inflammable gas leakage If the gas leaks and builds up around the unit it may catch fire Establish drain piping according to the instructions of this manual Inadequate piping may cause flooding 1

Скачать