Daikin EHSXB04P30A — установка и подключение систем управления отоплением и охлаждением [29/68]
![Daikin EHSX04P30A [29/68] X set up and installation](/views2/1786267/page29/bg1d.png)
Key names
Short
designation
Explanation Short
designation
Explanation
RoCon BM1
J9 Plug connection FLS (t
R1
/ V1) SG
Switching contact for Smart Grid (intelligent mains
co
nnection)
J10
Plug connection internal cabling
(to A1P)
TRA1 Transformer
J11
Plug connection internal cabling
(to RTX-AL4)
t
AU
External temperature sensor (RoCon OT1)
J12 Plug connection 3UV DHW t
DHW1
Storage tank temperature sensor 1 (RoCon BM1)
J13 Plug connection System-Bus (e.g. room station) t
DHW2
2 (A1P) storage tank temperature sensor
J14 Plug connection circulation pump P
Z
t
R1
Return flow temperature sensor 1 (FLS - RoCon
BM1)
J15 Plug connection internal cabling (strapping plug) t
R2
2 (A1P) return flow temperature sensor
J16
Plug connection room thermostat (EKRTR /
EKRTW)
t
V1
Flow temperature sensor 1 (RTX-AL4)
EHS157068 Mixer module t
V2
2 (A1P) flow temperature sensor
EHS157034 Room station t
V, BH
Flow temperature sensor Backup Heater (A1P)
Cooling out-
put
Output status for "Cooling" operating mode
V1 Flow sensor (FLS - RoCon BM1)
RT Room thermostat (EKRTW) XAG1 Plug connection exterior heat pump unit
RT-E Receiver for radio room thermostat (EKRTR) XBUH1 Plug connection backup heater (EKBUxx)
RTX-AL4 Switch board (interface) X2M6 Connecting cable clamp HPc-VK-1
RTX-AL4
J1 Plug connection to TRA1 X2M7 Connecting cable clamp HPc-VK-1
J3 Plug connection internal cabling (to A1P) X11M Terminal block in FWXV(15/20)AVEB
J6 Plug connection flow temperature sensor t
V1
RTX-EHS Switch board (Backup heater)
RTX-EHS
K1 Relay 1 for backup heater
K2 Relay 2 for backup heater
K3 Relay 3 for backup heater
X1
Terminal block for mains connection to backup
h
eater
X2_1
Plug connection internal cabling (to XBUH1)X2_2
X2_3
X3 Plug connection internal cabling to J3 (RTX-AL4)
Tab. 3-4 Key names for connections and circuit diagrams - Part 2
3 x Set-up and installation
Daikin Altherma EHS(X/H)
Daikin Solar tank with integrated interior heat pump unit
008.1420744 – 06/2015
Installation and maintenance manual
29
3.5 Laying coolant lines
● Check whether oil trap arc necessary.
– Required if Daikin Altherma EHS(X/H) is not installed at
ground level with the heat pump exterior unit (fig. 3-36,
H
O
≥ 10 m).
– At least one oil trap arc must be installed every 10 m dif-
ference in height (fig. 3-36, H = clearance from oil trap arc
to oil trap arc).
– Oil trap arc only required in gas line.
● In
stall lines with bending unit and an adequate clearance to
electrical lines.
● Only
solder with light nitrogen flow
(hard soldering only).
● Do not apply heat insulation to joins until after start-up (for
purposes of leakage search).
● Esta
blish flange connections and connect to the units.
( Pay attention to the tightening torque, see chapter 9.3
"Tightening torque").
Содержание
- Indoor unit for air water heat pumps daikin altherma integrated solar unit p.1
- Installation and maintenance manual p.1
- Malfunctions 43 p.3
- Tightening torque 63 p.3
- Emergency operation 54 p.3
- Temporary shutdown 35 p.3
- List of keywords 67 p.3
- Electrical connection 7 p.3
- Technical data 58 p.3
- List of contents p.3
- Dimensions and connections 3 p.3
- Start up 31 p.3
- Laying coolant lines 29 p.3
- Design and components p.3
- Set up and installation 13 p.3
- Intended use p.3
- Decommissioning 35 p.3
- Set up 5 p.3
- Instructions for operating safety p.3
- Circuit diagram daikin altherma ehs x h 64 p.3
- Service and maintenance 38 p.3
- Initial commissioning 31 p.3
- Characteristic lines 61 p.3
- Safety 4 p.3
- Hydraulic system connection 55 p.3
- Avoid danger p.3
- Removing the protective cover 38 p.3
- General 38 p.3
- Activities to be performed annually 38 p.3
- Recognising errors correcting malfunctions 42 p.3
- Final shutdown 37 p.3
- Filling the system with water 30 p.3
- Re commissioning 33 p.3
- Filling and topping up the storage tank 40 p.3
- Product description 7 p.3
- Filling and topping up the heating system 41 p.3
- Pressure test and filling the coolant circuit 30 p.3
- Fault codes 47 p.3
- Observing instructions p.3
- Errors malfunctions and messages 42 p.3
- Water connection 6 p.3
- Notes 65 p.3
- Warning signs and explanation of symbols p.3
- Monitoring and configuration dip switch 53 p.3
- Equipment data 58 p.3
- X safety p.4
- Warning signs and explanation of symbols p.4
- Validity p.4
- Special warning signs p.4
- Safety p.4
- Relevant documents p.4
- Observing instructions p.4
- Meaning of the warnings p.4
- Handling instructions p.4
- Intended use p.5
- Instructions for operating safety p.5
- Electrical installation p.5
- Before working on the hydraulic system p.5
- Avoid danger p.5
- X safety p.5
- X safety p.6
- Working on cooling systems heat pump p.6
- Site of installation p.6
- Requirements for the heating water p.6
- Operation p.6
- Instructing the user owner p.6
- Heating system and sanitary connection p.6
- X product description p.7
- Top of unit p.7
- Product description p.7
- Design and components p.7
- X product description p.8
- Fig 2 2 design and components of the daikin altherma ehs x h p30a external view and internal design for legend descriptions see tab 2 1 p.8
- Device external and internal design daikin altherma ehs x h p30a p.8
- Device external and internal design daikin altherma ehs x h b p30a p.9
- X product description p.9
- Fig 2 3 design and components of the daikin altherma ehs x h b p30a external view and internal design for legend descriptions see tab 2 1 p.9
- X product description p.10
- Fig 2 4 design and components of the daikin altherma ehs x h p50a external view and internal design for legend descriptions see tab 2 1 p.10
- Device external and internal design daikin altherma ehs x h p50a p.10
- X product description p.11
- Fig 2 5 design and components of the daikin altherma ehs x h b p50a external view and internal design for legend descriptions see tab 2 1 p.11
- Device external and internal design daikin altherma ehs x h b p50a p.11
- X product description p.12
- X set up and installation p.13
- Set up and installation p.13
- Dimensions and connections p.13
- Daikin altherma ehs x h p30a p.13
- Daikin altherma ehs x h p50a p.14
- X set up and installation p.14
- Scope of delivery p.15
- X set up and installation p.15
- Set up p.15
- X set up and installation p.16
- Water connection p.16
- X set up and installation p.17
- Electrical connection p.17
- Connecting hydraulic lines p.17
- X set up and installation p.18
- Overall connection plan daikin altherma ehs x h p.18
- Fig 3 7 overall connection diagram for electrical connection during device installation p.18
- Explanation of symbols and abbreviations in this chap ter see tab 3 2 and tab 3 3 p.18
- The a1p circuit board comes pre connected to the unit no as sembly or connection work is necessary on the a1p circuit board p.19
- Terminal assignment for the rtx ehs circuit board p.19
- Terminal assignment for the rtx al4 circuit board p.19
- Position of the circuit boards p.19
- Connection assignment circuit board a1p p.19
- X set up and installation p.19
- X set up and installation p.20
- Removing the protective cover p.20
- Mains connection daikin altherma ehs x h p.20
- Connection assignment circuit board rocon bm1 p.20
- X set up and installation p.21
- Opening the control housing and establishing electrical connections p.21
- Connection of external temperature sensor rocon ot1 p.21
- Connection of erlq exterior heat pump unit p.21
- X set up and installation p.22
- External demand signal eds p.22
- Connection of an external switching contact p.22
- Connection variant 2 p.23
- Connection variant 1 p.23
- Connection of the electrical daikin backup heater ekbuxx p.23
- Connection of an external heat generator p.23
- X set up and installation p.23
- X set up and installation p.24
- Caution p.24
- X set up and installation p.25
- Daikin room station ehs157034 p.25
- Daikin mixer module ehs157068 p.25
- Connection optional daikin rocon system components p.25
- Connection of the daikin room thermostat p.25
- X set up and installation p.26
- Low tariff mains connection ht nt p.26
- Internet gateway daikin ehs157056 p.26
- Connection switch contacts aux outputs p.26
- Connection of the daikin fwxv 15 20 aveb p.26
- C onnection of the daikin fwxv 15 20 aveb p.26
- Symbols and legend keys on connection and circuit diagrams p.27
- Connection intelligent controller smart grid sg p.27
- X set up and installation p.27
- X set up and installation p.28
- X set up and installation p.29
- Laying coolant lines p.29
- X set up and installation p.30
- Pressure test and filling the coolant circuit p.30
- Filling the system with water p.30
- Filling the storage tank p.30
- Filling the hot water heat exchanger p.30
- Filling the heating system p.30
- Checking the water quality and adjusting the pressure gauge p.30
- Start up p.31
- Set the commissioning parameters p.31
- Requirements p.31
- L commissioning p.31
- Initial commissioning p.31
- X start up p.31
- X start up p.32
- Venting the internal heating circulation pump p.32
- Expert p.32
- X start up p.33
- Start up p.33
- Requirements p.33
- Re commissioning p.33
- Configuring screed program parameters only if necessary p.33
- Check minimum flow p.33
- Activating the parameter air purge p.33
- X start up p.34
- Without solar installation p.35
- Temporary shutdown p.35
- Draining the storage tank p.35
- Decommissioning p.35
- X decommissioning p.35
- X decommissioning p.36
- Only for the solar installation p.36
- Draining the heating circuit and hot water circuit p.36
- X decommissioning p.37
- Recommendations for disposal p.37
- Final shutdown p.37
- X service and maintenance p.38
- Service and maintenance p.38
- Removing the protective cover p.38
- Legal requirements p.38
- General p.38
- Activities to be performed annually p.38
- X service and maintenance p.39
- With kfe filling connection or with installed solar system see also chapter 5 p.40
- Filling and topping up the storage tank p.40
- X service and maintenance p.40
- Without installed solar system p.40
- X service and maintenance p.41
- Filling and topping up the heating system p.41
- X errors malfunctions and messages p.42
- Troubleshooting p.42
- Recognising errors correcting malfunctions p.42
- Read protocol p.42
- Errors malfunctions and messages p.42
- Current fault display p.42
- X errors malfunctions and messages p.43
- Malfunctions p.43
- X errors malfunctions and messages p.44
- X errors malfunctions and messages p.45
- X errors malfunctions and messages p.46
- Fault codes p.47
- X errors malfunctions and messages p.47
- X errors malfunctions and messages p.48
- X errors malfunctions and messages p.49
- X errors malfunctions and messages p.50
- X errors malfunctions and messages p.51
- X errors malfunctions and messages p.52
- Touching live parts can result in an electric shock and lead to potentially fatal injuries and burns p.53
- Pump continuous running off p.53
- No designation factory setting p.53
- Monitoring and configuration dip switch p.53
- Domestic hot water gener ation on p.53
- Do not change off p.53
- Disconnect the system from the power supply open the control housing and remove the rocon bm1 board see chapter 3 check the dip switch setting on the a1p circuit board of the daikin altherma ehs x h adjust where necessary see tab 7 4 the factory preset may only be changed if e g an optional accessory was connected replace the rocon bm1 switch board close the control housing and reconnect the power supply p.53
- Dip switch settings are not recognised until a brief inter ruption to the power supply p.53
- Dip switch p.53
- Before beginning work on live parts disconnect all of the systems circuits from the power supply switch off main switch disconnect fuse and secure against unintentional restart p.53
- X errors malfunctions and messages p.53
- Warning p.53
- X errors malfunctions and messages p.54
- Emergency operation p.54
- X hydraulic system connection p.55
- Hydraulic system connection p.55
- X hydraulic system connection p.56
- X hydraulic system connection p.57
- X technical data p.58
- Technical data p.58
- Equipment data p.58
- Daikin altherma ehs x h p30a p.58
- X technical data p.59
- X technical data p.60
- Daikin altherma ehs x h p50a p.60
- Characteristic lines p.61
- X technical data p.61
- Sensor characteristic lines p.61
- X technical data p.62
- Sensor resistance in ohm p.62
- Sensor output frequency in hz p.62
- Pt 1000 p.62
- Measured temperature in c p.62
- Measured flow in l min p.62
- M l min p.62
- Fls sensor flow temperature p.62
- 14 229 hz p.62
- X technical data p.63
- Tightening torque p.63
- Characteristic curves for pumps p.63
- Fig 9 8 circuit diagram daikin altherma ehs x h for legend see tab 3 3 p.64
- Circuit diagram daikin altherma ehs x h p.64
- X technical data p.64
- X notes p.65
- X notes p.66
- X list of keywords p.67
- Numerics p.67
- List of keywords p.67
Похожие устройства
-
Daikin EVLQ08CAV3Руководство по применению для установщика -
Daikin EVLQ08CAV3Справочное руководство для монтажника -
Daikin EVLQ08CAV3Общие правила техники безопасности -
Daikin EVLQ08CAV3Инструкция по монтажу -
Daikin EVLQ05CAV3Справочное руководство для монтажника -
Daikin EVLQ05CAV3Руководство по применению для установщика -
Daikin EVLQ05CAV3Общие правила техники безопасности -
Daikin EVLQ05CAV3Инструкция по монтажу -
Daikin EHYKOMB33AA3Справочное руководство для монтажника -
Daikin EHYKOMB33AA3Руководство по применению для установщика -
Daikin EHYKOMB33AA3Руководство по эксплуатации -
Daikin EHYKOMB33AA2Руководство по применению для установщика
Подробное руководство по подключению и установке систем управления для отопления и охлаждения. Узнайте о ключевых соединениях и необходимых компонентах.