Daikin EHSXB04P30A — технические данные для систем отопления и охлаждения [59/68]

Daikin EHSX08P50A [59/68] X technical data
9 x Technical data
Daikin Altherma EHS(X/H)
Daikin Solar tank with integrated interior heat pump unit
008.1420744 – 06/2015
Installation and maintenance manual
59
Refrigerant circuit
Number of circuits 1
Pipe connections
Number 2
Liquid line
Type Flanged connection
External Ø inches 1/4" AG
Gas lines
Type Flanged connection
External Ø inches
5/8" AG
Operating data
Operating range
Flow temperature
for room hea
t-
ing/cooling function
Heating
(min./max.)
°C
15 to 55
Cooling
(min/max)
°C 5 to 22
Hot water genera-
tion (with EKBUxx)
Heating
(min./max.)
°C 25 to 80
Noise level
Audibility dBA 42
Noise pressure
2)
dBA 28
Electrical data:
Voltage supply
Phases 1
Voltage V 230
Voltage range V Voltage ±10%
Frequency Hz 50
Mains connection
3)
Exterior heat pump unit for Altherma
EHS(X/H)
4G
External unit for heat pump 3G
Optional auxiliary
heatin
g
Backup heater
(EKBUxx)
3G (1-phase) / 5G (3-phase)
1) T
CW
Cold water input temperature = 10 °C
T
DHW
Hot water draw-off temperature = 40 °C
T
S
Storage target temperature (charge state before
drawing off)
2) With a reference spacing of 1 m.
3) Number of individual wires in the conn
ection cable, including protective
earth. The cross-section of the individual lines is dependent on the current
load, the length of the connection cable and the respective legal provi-
sions.
Tab.
9-1 Basic data for the Daikin Altherma EHS(X/H)...P30A
Type Daikin Altherma EHS(X/H)
04P30A 08P30A B04P30A B08P30A