Daikin EKHWP500A [6/24] X safety

Daikin EKHWP500A [6/24] X safety
1 x Safety
Installation instructions
6
EKHWP300/500A
Hot water storage tank for air-water heat pumps and solar panels
4PW55928-1
Sanitary connection
With sanitary connection the following must be observed
EN 1717 -
Protection of domestic water from contamination in domestic water installations and general
requirements concerning safety equipment for the prevention of domestic water contamination
by back-flow
EN 806 - Technical regulations for domestic water installations (TRWI)
and, in addition, the country-specific legal regulations.
During operation of the hot water storage tank, the tank temperature may exceed 60 °C, particularly when solar power is
used. Therefore, some form of scalding protection needs to be included when you install the system (hot water mixing
device).
Use a pressure reducer if the cold water connection pressure >6 bar.
Operation
Do not operate the hot water storage tank if the storage tank is filled to above the overflow level.
Operate the hot water storage tank only with a set pressure reducer (max. 6 bar).
Instructing the user/owner
Before you hand over the heating system and the hot water storage tank, explain to the owner how he/she can operate and
check the heating system.
Document the hand-over by filling in and signing the checklist in Chapter 4 "Start-up and taking out of service“, together
with the operator.