CHARGING SYSTEM
OPERATION PROCEDURE OF CURRENT MEASUREMENT PROBE FOR CONSULT-II
For details, refer to the supplied “CONSULT-II Current Probe Operation Manual”.
1. Turn current probe power supply OFF and connect to CONSULT-II. (Red: CH1, Black: Ground)
2. Touch “SUB MODE”.
3. Touch “Extending Measurement Mode” on “SUB MODE” screen.
4. CAUTION is displayed, touch “OK”.
5. Set current probe range switch at the range to measure, turn
current probe power supply ON. When measuring dark current,
set 4A range. (Check that POWER indicator turns on. Refer to
CONSULT-II Current Probe Operation Manual.)
6. Touch the same measuring range at CONSULT-II.
NOTE:
If current probe measuring range is different from CONSULT-II
measuring range, incorrect value is displayed.
7. Adjust 0 point of current probe or CONSULT-II. (Do not clamp
anything to probe.)
NOTE:
If 0 point is dislocated greatly, adjust at current probe side gen-
erally.
8. Align current direction mark, clamp harness, and measure cur-
rent. If current direction is incorrect, it is displayed negative
value.
NOTE:
When current is measured, close probe joint securely.
If multiple harnesses are clamped, measurement cannot be
performed. Always clamp only one.
MKIA0071E
MKIA0072E
MKIA0073E
MKIA0074E