CHARGING SYSTEM
NOTE:
If dark current is greatly reduced when removing the fuse, and even if dark current is not greatly increased
when installing it again, the fuse circuit may be the cause.
6. Check that dark current changes when moving the suspect circuit harness. If dark current changes, check
harness for short. If dark current does not change, electronic unit in the circuit may not be entering the
energy-saving mode when it turns OFF. If it does not enter the energy-saving mode, replace electronic
unit.
7. No malfunction for alternator and electrical equipment. Electric load may be larger than alternator generat-
ing ability. Check the customer's usage.
OPERATION PROCEDURE OF CURRENT MEASUREMENT PROBE FOR CONSULT-II
For details, refer to the supplied “CONSULT-II Current Probe Operation Manual”.
1. Turn current probe power supply OFF and connect to CONSULT-II. (Red: CH1, Black: Ground)
2. Touch “SUB MODE”.
3. Touch “Extending Measurement Mode” on “SUB MODE” screen.
4. CAUTION is displayed, touch “OK”.
5. Set current probe range switch at the range to measure, turn
current probe power supply ON. When measuring dark current,
set 4A range. (Check that POWER indicator turns on. Refer to
CONSULT-II Current Probe Operation Manual.)
6. Touch the same measuring range at CONSULT-II.
NOTE:
If current probe measuring range is different from CONSULT-II
measuring range, incorrect value is displayed.
7. Adjust 0 point of current probe or CONSULT-II. (Do not clamp
anything to probe.)
NOTE:
If 0 point is dislocated greatly, adjust at current probe side gen-
erally.
MKIA0071E
MKIA0072E
MKIA0073E