4 | Operation
User reference guide
22
CHYHBH05+08AF + EHYKOMB33AA
Daikin Altherma R Hybrid
4P471762-1B – 2020.10
T
l
: Leaving water temperature
3 Press or to adjust/overrule.
To adjust the leaving water temperature (additional)
1 Go to the additional leaving water temperature home page (LWT add).
2 Press or to adjust. Example:
45°C 47°C
INFORMATION
In case of weather dependency, an offset value can be modified.
4.4.5 External room thermostat control - About external room thermostat control
External room thermostat control means that you control the following:
Room temperature on the external thermostat control
Leaving water temperature on the user interface (Daikin)
To control the leaving water temperature, you can do the following:
You can… Location
Read out the desired leaving water temperature. Leaving water
temperature home pages
(main + additional)
Adjust the desired leaving water temperature.
Only change this if the desired room temperature
cannot be reached.
See also: "4.4.4 Room thermostat control - Using the leaving water temperature
home pages"[420]
4.4.6 External room thermostat control - Using external room thermostat control
To adjust the leaving water temperature (main)
1 Go to the main leaving water temperature home page (LWT main).
To adjust the leaving water temperature (additional)
1 Go to the additional leaving water temperature home page (LWT add).
2 Press or to adjust. Example:
45°C 47°C
INFORMATION
In case of weather dependency, an offset value can be modified.
4.5 Domestic hot water control
NOTICE
Disinfection mode. Even if you turn OFF domestic hot water operation via the
DHWtank temperature home page (Tank), disinfection mode will remain active.