Daikin CHYHBH05AFV32 [26/56] Operation

Daikin CHYHBH05AFV32 [26/56] Operation
4 | Operation
User reference guide
26
CHYHBH05+08AF + EHYKOMB33AA
Daikin Altherma R Hybrid
4P471762-1B – 2020.10
To read out and overrule the active or next scheduled desired temperature (in
scheduled mode or scheduled + reheat mode)
1 Go to the DHWtank temperature home page (Tank).
Result:
60°C
is displayed.
t
a
b
T
t
A1
A2 B1 B2 A1A1 A2 B1 B2 A1
T
t
T
t
DHWtank temperature
t Time
During period… You can read out…
A1 The next scheduled action (a)
A2 The active action (a)
B1 The next scheduled action (b)
B2 The active action (b)
2 Press or to overrule.
Note: If the desired temperature is weather dependent, you cannot change it on
the home page.
Usage example: You need more hot water than scheduled
If you are in the following situation:
Current time = 10:30
Next scheduled action of the DHW tank = Heat up to the preset value (Eco;
example: 55°C and sufficient for 2 persons) at 14:00
This evening you need hot water for 3persons
Then you can do the following:
1 Go to the DHWtank temperature home page (Tank).
2 Overrule the next scheduled action by changing from 55°C to 60°C.
Advantages:
You will have sufficient hot water (=comfortable).
You do NOT have to change the schedule (=easy).
You do NOT have to activate the DHWtank booster mode (=energy saving).
Using the DHWtank booster mode
About the DHWtank booster mode
You can use the DHW tank booster mode to immediately start heating up the
water to the preset value (Storage comfort). However, this consumes extra
energy.
To check if the DHWtank booster mode is active
1 Go to the DHWtank temperature home page (Tank).
2 Check the following: