3 General safety precautions
Installation and operation manual
7
EHYKOMB33A
Daikin Altherma hybrid heat pump – gas boiler module
4P353067-1K – 2020.10
WARNING
▪ After finishing the electrical work, confirm that each
electrical component and terminal inside the electrical
components box is connected securely.
▪ Make sure all covers are closed before starting up the
unit.
NOTICE
Only applicable if the power supply is three‑phase, and the
compressor has an ON/OFF starting method.
If there exists the possibility of reversed phase after a
momentary black out and the power goes on and off while
the product is operating, attach a reversed phase
protection circuit locally. Running the product in reversed
phase can break the compressor and other parts.
3.2.5 Gas
The gas boiler is factory‑set to:
▪ the type of gas quoted on the type identification plate or on the
setting type identification plate,
▪ the gas pressure quoted on the type identification plate.
Operate the unit ONLY with the gas type and gas pressure indicated
on these type identification plates.
Installation and adaptation of the gas system MUST be conducted
by:
▪ personnel qualified for this work,
▪ in compliance with valid gas installation related guidelines,
▪ in accordance with applicable regulations of the gas supply
company,
▪ In accordance with local and national regulations.
Boilers that use natural gas MUST be connected to a governed
meter.
Boilers that use liquid petroleum gas (LPG) MUST be connected to a
regulator.
The size of the gas supply pipe should under no circumstance be
less than 22mm.
The meter or regulator and pipe work to the meter MUST be
checked preferably by the gas supplier. This is to ensure that the
equipment works good and meets the gas flow and pressure
requirements.
DANGER
If you smell gas:
▪ call immediately your local gas supplier and your
installer,
▪ call the suppliers's number on the side of the LPG tank
(if applicable),
▪ turn off the emergency control valve at the meter/
regulator,
▪ do NOT turn electrical switches ON or OFF,
▪ do NOT strike matches or smoke,
▪ put out naked flames,
▪ open doors and windows immediately,
▪ keep people away from the affected area.
3.2.6 Gas exhaust
Flue systems must NOT be modified or installed in any way other
than as described in the fitting instructions. Any misuses or
unauthorized modifications to the appliance, flue or associated
components and systems could invalidate the warranty. The
manufacturer accepts no liability arising from any such actions,
excluding statutory rights.
It is NOT allowed to combine flue system parts purchased from
different suppliers.
3.2.7 Local legislation
See the local and national regulations.
Local regulations for UK
It is law that all gas appliances are installed by a gas safe registered
competent engineer and in accordance with the following
recommendations:
▪ Current Gas Safety (Installation and Use) Regulations
▪ All current building regulations
▪ Building Standards (Scotland) Consolidated
▪ This appliance MUST be installed in accordance with the Gas
(Safety and Use) Regulations, current Building Regulations,
Building Standards (Scotland), I.S.813 Installation of Gas
Appliances (Ireland), IEE Wiring Regulations (BS 7671), Health
and Safety Document No. 635 (Electricity at Work Regulations)
and Local Water Authority Bye Laws
▪ UK Water Regulations and Bye Laws
▪ Health & Safety
The installation MUST comply with the following British Standards
codes of practice:
▪ BS 5440-1: 2008 Flueing and ventilation for gas appliances of
rated input not exceeding 70 kW net (1st, 2nd and 3rd family
gases)
▪ BS 5440-2: 2009 Flueing and ventilation for gas appliances of
rated input not exceeding 70 kW net (1st, 2nd and 3rd family
gases)
▪ BS 5546: 2010 Specification for installation and maintenance of
gas-fired water-heating appliances of rated input not exceeding
70kW net
▪ BS 5549: 1990 Forced circulation hot water systems.
▪ BS 6700: 2006 + A1: 2009 Design, installation, testing and
maintenance of services supplying water for domestic use within
buildings and their curtilages - Specification
▪ BS 6798: 2014 Specification for selection, installation, inspection,
commissioning, servicing and maintenance of gas-fired boilers of
rated input not exceeding 70kW net
▪ BS 6891: 2015 Specification for the installation and maintenance
of low pressure gas installation pipework of up to 35mm (R1¼) on
premises
▪ BS 7593: 2006 Code of practice for treatment of water in domestic
hot water space heating systems
▪ BS 7671: 2018 Requirements for electrical installations. IET wiring
regulations
▪ BS 7074: 1 Code of practice for domestic and hot water supply
▪ EN12828: 2014 Space heating for domestic premises
Potable water: all seals, joints and compounds (including flux and
solder) and components used as part of the secondary domestic
water system MUST be approved by WRAS.
Содержание
- Daikin altherma hybrid heat pump gas boiler 1
- Ehykomb33aa 1
- Installation and operation manual 1
- Module 1
- Boiler efficiency requirements 92 42 eec 2
- Daikin europe n v 2
- Director 2
- Ehykomb33aa 2
- Electromagnetic compatibility 2014 30 eu 2
- En60335 2 102 2
- Gas appliance regulation 2016 426 eu 2
- Installation and operation manual 2
- Low voltage 2014 35 eu 2
- Ostend 21st of april 2018 2
- P369568 3h 2
- Shigeki morita 2
- About the box 8 3
- About the documentation 4 3
- About the product 3
- About the product 3 3
- About the units and options 9 3
- Benchmark checklist can be used to demonstrate compliance with building regulations and should be provided to the customer for future reference 3
- Benchmark places responsibilities on both manufacturers and installers the purpose is to ensure that customers are provided with the correct equipment for their needs that it is installed commissioned and serviced in accordance with the manufacturer s instructions by competent persons and that it meets the requirements of the appropriate building regulations the 3
- Commissioning 31 3
- Configuration 25 3
- Especially for uk 3
- General safety precautions 4 3
- Glossary 36 3
- Installation 12 3
- Maintenance and service 32 3
- Operation 30 3
- Preparation 11 3
- Table of contents 3
- Technical data 38 3
- The benchmark scheme 3
- Troubleshooting 35 3
- About the documentation 4
- About this document 4
- General safety precautions 4
- Meaning of warnings and symbols 4
- For the installer 5
- General 5
- General safety precautions 5
- Installation site 5
- Electrical 6
- General safety precautions 6
- Gas exhaust 7
- General safety precautions 7
- Local legislation 7
- About the box 8
- Gas boiler 8
- To remove the accessories from the gas boiler 8
- To unpack the gas boiler 8
- About the units and options 9
- Combining units and options 9
- Identification 9
- Identification label gas boiler 9
- Possible options for the gas boiler 9
- About the units and options 10
- Preparation 11
- Preparing the gas boiler installation 11
- Installation 12
- Mounting the gas boiler 12
- Opening the units 12
- To install the gas boiler 12
- To open the gas boiler 12
- To open the switch box cover of the gas boiler 12
- Condensate pipe work 13
- Installation 13
- Internal connections 13
- To install the condensate trap 13
- Condensate pump 14
- Connecting the water piping of the gas boiler 14
- Connecting water piping 14
- External connections 14
- Installation 14
- To connect the water piping for domestic hot water not applicable for switzerland 14
- Connecting the electrical wiring 15
- Flow resistance graph for appliance domestic hot water circuit 15
- Installation 15
- To connect the communication cable between gas boiler and indoor unit 15
- To connect the main power supply of the gas boiler 15
- To connect the water piping for domestic hot water applicable for switzerland 15
- To connect the water piping for space heating 15
- To fill the domestic water circuit of the gas boiler 15
- Connecting the gas piping 16
- Installation 16
- To connect the gas pipe 16
- Connecting the boiler to the flue gas system 17
- Installation 17
- To change the 60 100 concentric connection to a dual pipe connection 17
- To change the gas boiler to 80 125 concentric connection 17
- Appliance categories and pipe lengths 18
- Calculate the total piping length 18
- Installation 18
- Installation 19
- Applicable materials 20
- Installation 20
- Fitting a horizontal flue system 21
- Flue pipe position 21
- Installation 21
- Insulation of the gas exhaust and air intake 21
- Fitting a vertical flue system 22
- Flue gas materials c63 available on the market 22
- Flues in voids 22
- Installation 22
- Plume management kit 22
- About securing the flue system 23
- Installation 23
- 1000 mm 24
- 3 50 mm m 24
- Finishing the gas boiler installation 24
- Installation 24
- To close the gas boiler 24
- Basic configuration 25
- Configuration 25
- Domestic hot water comfort function 25
- Gas boiler 25
- Overview configuration 25
- To install the cover plate 25
- To reset the gas boiler 25
- To turn on off the gas boiler 25
- Configuration 26
- Domestic hot water temperature 26
- Frost protection function 26
- Keep hot function 26
- Maximum space heating supply temperature 26
- To set the parameters via the service code 26
- Configuration 27
- Configuration 28
- Frost protection function 28
- Maximum space heating power setting 28
- To change to a different type of gas 28
- About the co ₂ setting 29
- Configuration 29
- Domestic hot water 30
- Heating 30
- Operation 30
- Operation modes 30
- Overview operation 30
- Commissioning 31
- To perform a gas pressure test 31
- Maintenance and service 32
- Maintenance safety precautions 32
- Opening the gas boiler 32
- To disassemble the gas boiler 32
- To perform a test run on the gas boiler 32
- Maintenance and service 33
- Maintenance and service 34
- To assemble the gas boiler 34
- To clean the inside of the gas boiler 34
- General guidelines 35
- Precautions when troubleshooting 35
- Solving problems based on symptoms 35
- Symptom no space heating by the gas boiler 35
- Symptom the burner does not ignite 35
- Symptom the burner ignites noisily 35
- Symptom the burner resonates 35
- Symptom the power is reduced 35
- Troubleshooting 35
- Error codes of the gas boiler 36
- Error codes overview 36
- Glossary 36
- Solving problems based on error codes 36
- Symptom hot water does not reach the temperature no tank installed 36
- Symptom no domestic hot water 36
- Symptom space heating does not reach the temperature 36
- Glossary 37
- A subset of the latest technical data is available on the regional daikin website publicly accessible the full set of latest technical data is available on the daikin business portal authentication required 38
- Components 38
- Components gas boiler 38
- Technical data 38
- General 39
- Technical data 39
- Technical specifications 39
- Technical specifications gas boiler 39
- Wiring diagram 39
- Wiring diagram gas boiler 39
- Appliance category and supply pressure 40
- Technical data 40
- Technical data 41
- Daikin altherma hybrid heat pump gas boiler module 42
- Ehykomb33a 42
- Gas boiler system commissioning checklist 42
- Installation and operation manual 42
- P353067 1k 2020 0 42
- Technical data 42
- This commissioning checklist is to be completed in full by the competent person who commissioned the boiler as a means of demonstrating compliance with the appropriate building regulations and then handed to the customer to keep for future reference 42
- Ehykomb33a daikin altherma hybrid heat pump gas boiler module 4p353067 1k 2020 0 43
- Installation and operation manual 43
- Service 01 43
- Service 02 43
- Service 03 43
- Service 04 43
- Service 05 43
- Service 06 43
- Service 07 43
- Service 08 43
- Service 09 43
- Service 10 43
- Service record 43
- Technical data 43
Похожие устройства
- Daikin EHYKOMB33AA3 Руководство по применению для установщика
- Daikin EHYKOMB33AA3 Справочное руководство для монтажника
- Daikin EKBALLV1 Инструкция по монтажу
- Daikin EKBPHT04JH Инструкция по монтажу
- Daikin EKDPH008C Инструкция по монтажу
- Daikin EKEPHYHT35H Инструкция по монтажу
- Daikin EKHY3PART Инструкция по монтажу
- Daikin EKHY075787 Инструкция по монтажу
- Daikin EKHY075787 Брошюра
- Daikin EKPS075867 Инструкция по монтажу
- Daikin EKPS075867 Брошюра
- Daikin EKPS075877 Инструкция по монтажу
- Daikin EKPS075877 Брошюра
- Daikin EKPS075917 Инструкция по монтажу
- Daikin EKPS075917 Брошюра
- Daikin EKPS076197 Инструкция по монтажу
- Daikin EKPS076197 Брошюра
- Daikin EKPS076207 Инструкция по монтажу
- Daikin EKPS076207 Брошюра
- Daikin EKPS076217 Инструкция по монтажу