Daikin ERRQ011AAY1 — энергоэффективные наружные блоки для отопления [141/459]

Daikin ERRQ011AAY1 [141/459] 3 electrical specifications
Daikin Altherma Low Temperature • Outdoor units • ERHQ006-016BAV3
Heating Daikin Altherma
138
2 Specifications
9
2
Standard Accessories Item Installation
manual
Installation
manual
Installation
manual
Tie-wraps Tie-wraps Tie-wraps
Quantity 111222
Item Drain plug Drain plug Drain plug Installation
manual
Installation
manual
Installation
manual
Quantity 111111
Notes See operation
range drawing
See operation
range drawing
See operation
range drawing
The sound
pressure level
is measured
via a
microphone at
a certain
distance from
the unit. It is a
relative value
depending on
the distance
and acoustic
environment.
Refer to sound
spectrum
drawing for
more
information.
The sound
pressure level
is measured
via a
microphone at
a certain
distance from
the unit. It is a
relative value
depending on
the distance
and acoustic
environment.
Refer to sound
spectrum
drawing for
more
information.
The sound
pressure level
is measured
via a
microphone at
a certain
distance from
the unit. It is a
relative value
depending on
the distance
and acoustic
environment.
Refer to sound
spectrum
drawing for
more
information.
The sound
pressure level
is measured
via a
microphone at
a certain
distance from
the unit. It is a
relative value
depending on
the distance
and acoustic
environment.
Refer to sound
spectrum
drawing for
more
information.
The sound
pressure level
is measured
via a
microphone at
a certain
distance from
the unit. It is a
relative value
depending on
the distance
and acoustic
environment.
Refer to sound
spectrum
drawing for
more
information.
The sound
pressure level
is measured
via a
microphone at
a certain
distance from
the unit. It is a
relative value
depending on
the distance
and acoustic
environment.
Refer to sound
spectrum
drawing for
more
information.
Down to 3m
with recharging
of the outdoor
unit. Refer to
the installation
manual of the
outdoor unit.
Down to 3m
with recharging
of the outdoor
unit. Refer to
the installation
manual of the
outdoor unit.
Down to 3m
with recharging
of the outdoor
unit. Refer to
the installation
manual of the
outdoor unit.
2-3 ELECTRICAL SPECIFICATIONS ERHQ006BAV3 ERHQ007BAV3 ERHQ008BAV3 ERHQ011BAV3 ERHQ014BAV3 ERHQ016BAV3
Power Supply Name V3
Phase 1~
Frequency Hz 50 50 50 50 50 50
Voltage V 230 230 230 230 230 230
Voltage range Minimum V -10%
Maximum V +10%
2-2 TECHNICAL SPECIFICATIONS ERHQ006BAV3 ERHQ007BAV3 ERHQ008BAV3 ERHQ011BAV3 ERHQ014BAV3 ERHQ016BAV3