Daikin ERRQ011AAY1 [397/459] Capacity tables

Daikin ERSQ014AAY1 [397/459] Capacity tables
Domestic Hot Water Tank • EKHTS-A
Heating Daikin Altherma
394
3 Capacity tables
3 - 1 Heating capacity tables
21
3
3TW58802-1A
Altherma HT-TW Domestic hot water tank
The DAIKIN ALTHERMA heat pump in combination with the optional domestic hot water tank provide hot water for household usage.
The below mentioned date allow a proper selection of the domestic hot water tank size for maximum comfort and efficiency.
(1) Capacity:
EKHTS*200 EKHTS*260
Total capacity (L) 210 258
Actual capacity (L) 193,5 250,5
Total capacity = internal volume of tank(= effective water volume+ coil volume)
Actual capacity=effective water volume inside the tank
(2) Maximum volume of usable hot water:
The volume of hot water available for domestic usage depends on the physical volume of the tank, on the domestic water setpoint temperature and on the temperature spreading
in the tank.
Definition:
Maximum volume of usable hot water = the volume of hot water available for domestic usage at a temperature of 40°C.
40°C is considered a comfortable domestic hot water temperature. (cold water inlet temp = 10°C)
Tank
Setpoint temp.
Maximum volume of
usable hot water
Tapping pattern*
Small Medium High very high
EKHTS*200
40 190 +++ + - -
50 255 +++ ++ - -
60 320 +++ +++ - -
70 385 +++ +++ + -
EKHTS*260
40 250 +++ ++ - -
50 330 +++ +++ - -
60 415 +++ +++ ++ -
70 500 +++ +++ ++ +
Grade +++ more than excessive availability of sanitary hot water (more than 40% of EHWV is still available after tapping pattern)
++ Excessive availability of sanitary hot water. (10%< EHWV still available after tapping pattern<40%)
+
Sufficient availability of sanitary hot water.
(EHWV still available after tapping pattern <10%)
- Temporary shortage of sanitary hot water can occur.
Tapping pattern** Small Daily demand up to 90l -> typical 1-person daily usage pattern
Medium Daily demand up to 190l -> typical 2-persons daily usage pattern
High Daily demand up to 370l -> typical 3 to 4 persons daily usage pattern
very high Daily demand up to 500l -> 5 to 6 persons daily usage pattern
* based upon heat up to tank once / 24 hours
** Heat losses (over 24 hrs) are included in the tapping patterns
(3) Standing Heat loss:
Tank
Heat losses
[kWh/24h]
EKHTS*200 1.2
EKHTS*260 1.5
* heat loss of tank at_T = 45K
(4) Heat-up time:
Definition:
Heat-up time = The time is required to heat up the domestic hot water tank from 15°C to 60°C (minutes)
Tank
Heat-up time <min>
EKHBRD11 EKHBRD14 EKHBRD16
EKHTS*200 60 50 40
EKHTS*260 70 60 50
conditions for testing: Ta = 7°CDB / 6°CWB, TStart = 15°C
(5) Reheat time:
Definition:
Reheat time = The time required to reheat the deomestic hot water tank back to 60°C after tapping 70% of the actual volume.
Tank
Reheat time <min>
EKHBRD11 EKHBRD14 EKHBRD16
EKHTS*200 50 40 30
EKHTS*260 60 50 40
Starting condition before tapping 70% of volume: tank at 60°C
conditions for testing: Ta = 7°CDB / 6°CWB, TCold = 15°C