Daikin ERRQ011AAY1 [63/459] Specifications
Indoor units • EKHBRD-AAV1
Heating • Daikin Altherma
60
2 Specifications
5
2
Refrigerant Circuit Gas side diameter mm 15,9
Liquid side diameter mm 9,52
High pressure side Design pressure bar 38 38 38
Sound level Sound Pressure dBA 43(1) / 46(2) 45(1) / 46(2) 46(1) / 46(2)
Sound Level Night
Quiet
Sound Pressure dBA 40 43 45
Ambient Heating Min °C -20 -20 -20
Max °C 20 20 20
Domestic hot water Min °C -20 -20 -20
Max °C 35 35 35
Waterside Heating Min °C 25 25 25
Max °C 80 80 80
Domestic hot water Min °C 25 25 25
Max °C 80 80 80
Installation place Indoor
Notes Nominal water flow rate for Dt = 10°C
Maximum water flow rate for Dt = 5°C
(1) Sound levels are measured at condition 1: EW: 55°C; LW: 65°C
(2) Sound levels are measured at condition 3: EW: 70°C; LW: 80°C
Sound level in night quiet mode is measured at condition 1: EW: 55°C; LW: 65°C
Sound level is valid in free field condition because it is measured in a semi-anechoic room. Measured
value under actual installation conditions will be higher due to environmental noise and sound
reflections. Values are sound pressure values measured at all sides (front, back, left, right, top) at 1m
distance. The values do not occur simultaneously on all mentioned sides.
For details on operation range: cf. TW drawing
2-2 Electrical Specifications EKHBRD011AAV1 EKHBRD014AAV1 EKHBRD016AAV1
Power Supply Name V1
Phase 1~
Frequency Hz 50 50 50
Voltage V 220-240
Current Minimum Ssc value Equipment complying with EN/IEC 61000-3-12 **
Maximum running
Current
Heating A 22.5 23.8 23.8
Recomended fuses A 25 25 25
Voltage range Minimum 198
Maximum 254
Wiring connections For Power Supply Quantity 2G
Type of wires (3) Select diameter and type according to national and local regulations
Quantity 2G + 2G
Connection type For power supply with benefit kWh rates
Type of wires (3) Select diameter and type according to national and local regulations
Power Supply Intake Both indoor and outdoor unit
Wiring connections Connection type For connection with outdoor unit
Quantity of wires 2 2 2
Type of wires F1+F2
Notes (**) European/International Technical Standard setting the limits for harmonic currents produced by
equipment connected to public low-voltage systems with input current >16A and <= 75A per phase
In accordance with EN/IEC 61000-3-11(*), it may be necessary to consult the distribution network
operator to ensure that the equipment is connected only to a supply with Zsys(***) <= Zmax
Ssc: Short-circuit power
(*) European/International Technical Standard setting the limits for voltage changes, voltage fluctuations
and flicker in public low-voltage supply systems for equipment with rated current <= 75A
(***) System impedance
2-1 Technical Specifications EKHBRD011AAV1 EKHBRD014AAV1 EKHBRD016AAV1
101727_BW_EN_004_464_IC.pdf 64 9/06/2010 14:53:46