Daikin ERRQ011AAY1 [252/459] Specifications

Daikin ERRQ016AAY1 [252/459] Specifications
Heating Daikin Altherma
249
Daikin Altherma Low Temperature • Monobloc • EDHQ011-016BA6V3
2 Specifications
14
2
Water circuit Piping connections inch G5/4 (FEMALE)
Piping inch 5/4"
Safety valve bar 3 3 3
Manometer Yes
Drain valve / Fill valve Yes
Shut off valve Yes
Air purge valve Yes
Total water volume (6) l 5.5 5.5 5.5
Minimum water volume system l 20 20 20
2-4 ELECTRICAL SPECIFICATIONS EDHQ011BA6V3 EDHQ014BA6V3 EDHQ016BA6V3
Power supply
compressor
component
Main Power Name V3
Phase 1~1~1~
Frequency Hz 50 50 50
Voltage V 230 230 230
Voltage range Minimum V -10%
Maximum V +10%
Current Minimum Ssc
value
kVa Equipment complying with EN/IEC 61000-3-12(*)
Recomended
fuses
A32 32 32
Wiring connections For power supply
compressor component
See installation manual
Power supply
hydraulic component
Current back-up
heater
Type 6V3
Current back-up
heater
Power Supply Phase 1~
Frequency Hz 50 50 50
Voltage V 230 230 230
Running Current Back-up
heater
A26 26 26
Running Current Back-up heater +
booster heater
+EK*V3 A 39(26+13)
Current back-up
heater
Z-max Back-up
heater
A 0.29 0.29 0.29
Back-up
heater +
booster
heater
A 0.17 0.17 0.17
Minimum Ssc value +EK*V3 kVa Equipment complying with EN/IEC 61000-3-12(**)
2-3 MAIN COMPONENTS EDHQ011BA6V3 EDHQ014BA6V3 EDHQ016BA6V3