Panasonic WH-MXF12D3E8 [110/118] Heating capacity table

Panasonic WH-MXF12D3E8 [110/118] Heating capacity table
110
18.2 Heating Capacity Table
18.2.1 WH-MXF09D3E8
Water
Out
30 35 40 45 50 55
Outdoor
Air
Capacity
Input
Power
Capacity
Input
Power
Capacity
Input
Power
Capacity
Input
Power
Capacity
Input
Power
Capacity
Input
Power
-15 9000 3280 9000 3550 9000 3950 9000 4340 9000 4770 9000 5200
-7 9000 2750 9000 3200 9000 3660 9000 4110 9000 4310 9000 4500
2 9000 2400 9000 2550 9000 2820 9000 3090 9000 3600 9000 4110
7 9000 1680 9000 1900 9000 2200 9000 2500 9000 2880 9000 3100
25 13600 1540 13600 1750 13200 1970 12800 2180 12000 2450 11200 2710
18.2.2 WH-MXF12D9E8
Water
Out
30 35 40 45 50 55
Outdoor
Air
Capacity
Input
Power
Capacity
Input
Power
Capacity
Input
Power
Capacity
Input
Power
Capacity
Input
Power
Capacity
Input
Power
-15 12000 4790 12000 5000 12000 5450 12000 5900 11500 6280 11100 6660
-7 12000 3890 12000 4450 12000 5020 12000 5580 12000 5940 12000 6300
2 12000 3230 12000 3530 12000 3910 12000 4290 12000 4900 12000 5510
7 12000 2220 12000 2570 12000 3000 12000 3430 12000 3820 12000 4200
25 13600 1590 13600 1800 13400 2140 13200 2470 12600 2700 12000 2930
18.3 Hydraulic Pump Performance
0 10203040506070
0
10
20
30
40
50
60
70
80
90
WATER FLOW RATE (L/min)
EXTERNA
L
STATIC
PRESSURE (kPa)
PUMP SPEED 3
PUMP SPEED 2
PUMP SPEED 1