Graco Reactor 2 H-40 APH046 [20/34] Connect hoses to proportioner

Graco Reactor 2 H-40 PHH144 [20/34] Connect hoses to proportioner
Installation
20 309572ZAT
Connect Hoses to Proportioner
1. Grease with Fusion
®
grease and connect fluid
hoses to proportioner fluid manifold (M). Red for
hardener (ISO), blue for resin (RES).
NOTE: The manifold hose adapters (N, P) allow use of
1/4 in (6.4 mm). and 3/8 in. (9.5 mm) ID fluid hoses. To
check adapter tightness, torque 1/4 in. and 3/8 in. ID
hoses to:
A side (N) to 14 ft-lb (19 N•m).
B side (P) to 20 ft-lb (27 N•m).
To use 1/2 in. (13 mm) ID fluid hoses, remove the
adapters (N, P) from the proportioner fluid manifold and
install them in the FTS or 3/8 in. ID hose inlets. Torque
1/2 in. ID hoses to:
A side (N) to 43 ft-lb (58 N•m).
B side (P) to 55 ft-lb (74 N•m).
NOTE: For proportioners with termination box (TB),
follow step 2, For proportioners with electrical splice
connectors (12) follow step 3.
2. Connect hose power wires to terminal block (C) on
termination box (TB). Remove box cover (D) and
loosen lower strain relief (E). Route wires through
strain relief and fully insert into terminal block (A and
B hose wire positions are not important). Torque
terminal connector screws (C) to 26-30 in-lb (2.9-3.3
N•m). Fully tighten strain relief screws and replace
cover.
3. Connect hose power wires to electrical splice
connectors (12) from proportioner or accessory
control box. See Connect Heated Hoses, page 13,
step 5. Connect FTS hose cable (4) to cable from
proportioner or accessory control box. Wrap
connections with electrical tape.
4. Connect FTS cable connectors. Fully tighten RTD
connectors, if provided.
If thermocouple (non-RTD) FTS connectors are
provided, fully tighten connectors and slide
connector covers over the joint.
5. Check that all equipment is properly grounded. See
proportioner manual.
M
N
P
M
4
3
12
T

Содержание

Скачать