Graco Reactor 2 H-40 APH046 [8/34] Warning warning warning warning
![Graco Reactor 2 H-40 APH046 [8/34] Warning warning warning warning](/views2/1900952/page8/bg8.png)
Warnings
8 309572ZAT
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled or
swallowed.
• Read Safety Data Sheet (SDS) for handling instructions and to know the specific hazards of the fluids
you are using, including the effects of long-term exposure.
• When spraying, servicing equipment, or when in the work area, always keep work area well
ventilated and always wear appropriate personal protective equipment. See Personal Protective
Equipment warnings in this manual.
• Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. Paint or
solvent flowing through the equipment can cause static sparking. To help prevent fire and explosion:
• Use equipment only in well ventilated area.
• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop
cloths (potential static sparking).
• Ground all equipment in the work area. See Grounding instructions.
• Never spray or flush solvent at high pressure.
• Keep work area free of debris, including solvent, rags and gasoline.
• Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes
are present.
• Use only grounded hoses.
• Hold gun firmly to side of grounded pail when triggering into pail. Do not use pail liners unless they
are anti-static or conductive.
• Stop operation immediately if static sparking occurs or you feel a shock. Do not use equipment until
you identify and correct the problem.
• Keep a working fire extinguisher in the work area.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
• Do not operate the unit when fatigued or under the influence of drugs or alcohol.
• Do not exceed the maximum working pressure or temperature rating of the lowest rated system
component. See Technical Data in all equipment manuals.
• Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information
about your material, request Safety Data Sheet (SDS) from distributor or retailer.
• Do not leave the work area while equipment is energized or under pressure.
• Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.
• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine
manufacturer’s replacement parts only.
• Do not alter or modify equipment. Alterations or modifications may void agency approvals and create
safety hazards.
• Make sure all equipment is rated and approved for the environment in which you are using it.
• Use equipment only for its intended purpose. Call your distributor for information.
• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
• Do not kink or over bend hoses or use hoses to pull equipment.
• Keep children and animals away from work area.
• Comply with all applicable safety regulations.
WARNINGWARNINGWARNING
WARNING
Содержание
- Heated hose 1
- Instructions 1
- Power loc 1
- Contents 2
- Adapter fittings 3
- Power lock hose bundle part numbers 3
- Use adapter fittings to connect a hose assembly to a fluid manifold and or a fts use jic swivel fittings to connect a female fts to male end hoses and or npt female ball valves on mix manifold inlets 3
- Whip hoses 3
- You need at least one 50 ft 15 m main hose one fluid temperature sensor fts and one whip hose or one wire harness jumper part no 261821 to make a complete heated hose assembly be sure the selected hose meets your maximum pressure and hose diameter requirements 3
- Airless 2 component hose 4
- Standard 2 component hose 4
- Custom application 2 component hose 5
- Rtd 2 component hose for use with gca controlled reactors 5
- Two fts cables and two sets of standard wires 5
- Fluid temperature sensor fts kits 6
- Fluid temperature sensor kits fts rtd for use with gca controlled systems 6
- Fts kits contain 6
- Warning warning warning warning 7
- Warnings 7
- Warning warning warning warning 8
- Warning warning warning warning 9
- Important isocyanate iso information 10
- Isocyanate conditions 10
- Changing materials 11
- Foam resins with 245 fa blowing agents 11
- Keep components a and b separate 11
- Material self ignition 11
- Moisture sensitivity of isocyanates 11
- Notice 11
- Connect whip hose to gun or gun manifold 12
- Description 12
- Installation 12
- Connect heated hoses 13
- Cap plugs 15
- Setscrews 15
- Connect fts and heated dual whip hose 17
- Notice 17
- Non rtd thermocouple 2 component hoses 18
- Connect fts with a non heated whip hose or remote mix manifold 19
- Notice 19
- Connect hoses to proportioner 20
- Check hoses for leaks 21
- Fluid temperature sensor fts calibration non rtd versions 21
- For non scuffed hoses 21
- Protective covering 21
- Operation 22
- Instructions for replacing individual a or b hose 23
- Maintenance 23
- Fluid temperature sensor 24
- Heated fluid hose 24
- Using 261669 fluid temperature sensor jic to jic fittings 24
- Whip hose 24
- Fluid temperature sensor 25
- Heated fluid hose 25
- Using 24m943 fluid temperature sensor npt to npt fittings 25
- Whip hose 25
- Fluid temperature sensor 26
- Heated fluid hose 26
- Using 24k207 rtd 2 component hose fluid temperature sensor jic to jic fittings 26
- Whip hose 26
- Fluid temperature sensor 27
- Heated fluid hose 27
- Using 24m944 rtd 2 component hose fluid temperature sensor npt to npt fittings 27
- Whip hose 27
- Fluid temperature sensor 28
- Heated fluid hose 28
- Using 261670 fluid temperature sensor jic to npt fittings 28
- F144 hose wire jumper 29
- Installation 29
- Accessories 31
- Scuff guard protective cover 31
- Technical specifications 32
- Total heating load 2 hoses 32
- California proposition 65 33
- California residents 33
- Warning cancer and reproductive harm www p65warnings ca gov 33
- For the latest information about graco products visit www graco com for patent information see www graco com patents 34
- Graco headquarters minneapolis international offices belgium china japan korea 34
- Graco inc and subsidiaries p o box 1441 minneapolis mn 55440 1441 usa copyright 2002 graco inc all graco manufacturing locations are registered to iso 9001 www graco com revision zat january 2021 34
- Graco information 34
- Graco standard warranty 34
- To place an order contact your graco distributor or call to identify the nearest distributor phone 612 623 6921 or toll free 1 800 328 0211 fax 612 378 3505 34
Похожие устройства
- Graco Reactor 2 H-40 APH046 Брошюра
- Graco Reactor 2 H-40 APH143 Инструкция по эксплуатации
- Graco Reactor 2 H-40 APH143 Брошюра
- Graco Reactor 2 H-40 APH143 Сертификат
- Graco Reactor 2 H-40 APH143 Техническая документация
- Graco Reactor 2 H-40 APH144 Инструкция по эксплуатации
- Graco Reactor 2 H-40 APH144 Брошюра
- Graco Reactor 2 H-40 APH144 Сертификат
- Graco Reactor 2 H-40 APH144 Техническая документация
- Graco Reactor 2 H-40 APH145 Инструкция по эксплуатации
- Graco Reactor 2 H-40 APH145 Брошюра
- Graco Reactor 2 H-40 APH145 Сертификат
- Graco Reactor 2 H-40 APH145 Техническая документация
- Graco Reactor 2 H-40 APH146 Инструкция по эксплуатации
- Graco Reactor 2 H-40 APH146 Брошюра
- Graco Reactor 2 H-40 APH146 Сертификат
- Graco Reactor 2 H-40 APH146 Техническая документация
- Graco Reactor 2 H-40 FHH043 Инструкция по эксплуатации
- Graco Reactor 2 H-40 FHH043 Брошюра
- Graco Reactor 2 H-40 FHH043 Сертификат