Graco Reactor 2 H-40 APH046 [7/34] Warnings
![Graco Reactor 2 H-40 FPH144 [7/34] Warnings](/views2/1900952/page7/bg7.png)
Warnings
309572ZAT 7
Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The
exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk.
When these symbols appear in the body of this manual, refer back to these Warnings. Product-specific hazard
symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
WARNINGWARNINGWARNING
WARNING
ELECTRIC SHOCK HAZARD
The hoses must be grounded. Improper grounding, set-up, or usage of hoses can cause electric
shock.
• Turn off and disconnect power before installing or servicing hoses.
• Connect only to grounded power source.
• All electrical wiring must be done by a qualified electrician and comply with all local codes and
regulations.
• Never cut or puncture a hose cover.
• Do not expose to rain. Store indoors.
SKIN INJECTION HAZARD
High-pressure fluid from hose leaks, or ruptured components will pierce skin. This may look like just a
cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.
• Inspect hose before each use for cuts, bulges, kinks or any other damage.
• Replace damaged hose immediately.
• Replace hoses proactively at regular intervals based on your operating conditions.
• Tighten all fluid connections before operating the equipment.
• Keep clear of leaks.
• Do not stop or deflect leaks with your hand, body, glove, or rag.
• Never exceed hose Maximum Pressure or Temperature ratings.
• Only use chemicals that are compatible with hose materials. See Technical Data in this manual.
Read Safety Data Sheet (SDS) and fluid and solvent manufacturer’s recommendations.
• Follow the Pressure Relief Procedure when you stop spraying/dispensing and before cleaning,
checking, or servicing equipment.
THERMAL EXPANSION HAZARD
Fluids subjected to heat in confined spaces, including hoses, can create a rapid rise in pressure due to
the thermal expansion. Over-pressurization can result in equipment rupture and serious injury.
• Open a valve to relieve the fluid expansion during heating.
• Replace hoses proactively at regular intervals based on your operating conditions.
BURN HAZARD
Equipment surfaces and fluid that is heated can become very hot during operation. To avoid severe
burns:
• Do not touch hot fluid or equipment.
Содержание
- Heated hose 1
- Instructions 1
- Power loc 1
- Contents 2
- Adapter fittings 3
- Power lock hose bundle part numbers 3
- Use adapter fittings to connect a hose assembly to a fluid manifold and or a fts use jic swivel fittings to connect a female fts to male end hoses and or npt female ball valves on mix manifold inlets 3
- Whip hoses 3
- You need at least one 50 ft 15 m main hose one fluid temperature sensor fts and one whip hose or one wire harness jumper part no 261821 to make a complete heated hose assembly be sure the selected hose meets your maximum pressure and hose diameter requirements 3
- Airless 2 component hose 4
- Standard 2 component hose 4
- Custom application 2 component hose 5
- Rtd 2 component hose for use with gca controlled reactors 5
- Two fts cables and two sets of standard wires 5
- Fluid temperature sensor fts kits 6
- Fluid temperature sensor kits fts rtd for use with gca controlled systems 6
- Fts kits contain 6
- Warning warning warning warning 7
- Warnings 7
- Warning warning warning warning 8
- Warning warning warning warning 9
- Important isocyanate iso information 10
- Isocyanate conditions 10
- Changing materials 11
- Foam resins with 245 fa blowing agents 11
- Keep components a and b separate 11
- Material self ignition 11
- Moisture sensitivity of isocyanates 11
- Notice 11
- Connect whip hose to gun or gun manifold 12
- Description 12
- Installation 12
- Connect heated hoses 13
- Cap plugs 15
- Setscrews 15
- Connect fts and heated dual whip hose 17
- Notice 17
- Non rtd thermocouple 2 component hoses 18
- Connect fts with a non heated whip hose or remote mix manifold 19
- Notice 19
- Connect hoses to proportioner 20
- Check hoses for leaks 21
- Fluid temperature sensor fts calibration non rtd versions 21
- For non scuffed hoses 21
- Protective covering 21
- Operation 22
- Instructions for replacing individual a or b hose 23
- Maintenance 23
- Fluid temperature sensor 24
- Heated fluid hose 24
- Using 261669 fluid temperature sensor jic to jic fittings 24
- Whip hose 24
- Fluid temperature sensor 25
- Heated fluid hose 25
- Using 24m943 fluid temperature sensor npt to npt fittings 25
- Whip hose 25
- Fluid temperature sensor 26
- Heated fluid hose 26
- Using 24k207 rtd 2 component hose fluid temperature sensor jic to jic fittings 26
- Whip hose 26
- Fluid temperature sensor 27
- Heated fluid hose 27
- Using 24m944 rtd 2 component hose fluid temperature sensor npt to npt fittings 27
- Whip hose 27
- Fluid temperature sensor 28
- Heated fluid hose 28
- Using 261670 fluid temperature sensor jic to npt fittings 28
- F144 hose wire jumper 29
- Installation 29
- Accessories 31
- Scuff guard protective cover 31
- Technical specifications 32
- Total heating load 2 hoses 32
- California proposition 65 33
- California residents 33
- Warning cancer and reproductive harm www p65warnings ca gov 33
- For the latest information about graco products visit www graco com for patent information see www graco com patents 34
- Graco headquarters minneapolis international offices belgium china japan korea 34
- Graco inc and subsidiaries p o box 1441 minneapolis mn 55440 1441 usa copyright 2002 graco inc all graco manufacturing locations are registered to iso 9001 www graco com revision zat january 2021 34
- Graco information 34
- Graco standard warranty 34
- To place an order contact your graco distributor or call to identify the nearest distributor phone 612 623 6921 or toll free 1 800 328 0211 fax 612 378 3505 34
Похожие устройства
- Graco Reactor 2 H-40 APH046 Брошюра
- Graco Reactor 2 H-40 APH143 Инструкция по эксплуатации
- Graco Reactor 2 H-40 APH143 Брошюра
- Graco Reactor 2 H-40 APH143 Сертификат
- Graco Reactor 2 H-40 APH143 Техническая документация
- Graco Reactor 2 H-40 APH144 Инструкция по эксплуатации
- Graco Reactor 2 H-40 APH144 Брошюра
- Graco Reactor 2 H-40 APH144 Сертификат
- Graco Reactor 2 H-40 APH144 Техническая документация
- Graco Reactor 2 H-40 APH145 Инструкция по эксплуатации
- Graco Reactor 2 H-40 APH145 Брошюра
- Graco Reactor 2 H-40 APH145 Сертификат
- Graco Reactor 2 H-40 APH145 Техническая документация
- Graco Reactor 2 H-40 APH146 Инструкция по эксплуатации
- Graco Reactor 2 H-40 APH146 Брошюра
- Graco Reactor 2 H-40 APH146 Сертификат
- Graco Reactor 2 H-40 APH146 Техническая документация
- Graco Reactor 2 H-40 FHH043 Инструкция по эксплуатации
- Graco Reactor 2 H-40 FHH043 Брошюра
- Graco Reactor 2 H-40 FHH043 Сертификат