Aten VK236 [353/378] Vk2200

Aten VK1100A [353/378] Vk2200
Appendix
327
I/O 8 x Programmable Digital Input / Output
Channels (2 x 5-Pole Terminal Block Connectors)
Digital Output: 300 mA sink from 24 V DC
Digital Input:
VDC Mode
Input Voltage Range: 0 ~ 24 V DC
Programmable Range: 1 ~ 24 V DC
Dry Contact Mode
Pull-up 2 kΩ to +12 V DC
Relay
8 x Relay Channels (4 x 4-Pole Terminal
Block Connector)
Normally Open, Isolated Relays
Contact Rating: Max 24 V DC, 2 A
V DC
4 x 12 V DC Output Ports (2 x 4-Pole Terminal
Block Connectors)
Power Supply: 12 V DC, 2 A Max (Shared By
4 Ports)
Ethernet
2 x RJ-45 Female, 10/100/1000 Base-T
Supported protocol: ARP, ICMP, TCP/IP,
DHCP, HTTPS, SSH
DHCP-enabled. Default IP settings (IP
address 192.168.0.60 / 192.168.1.60 for
Control LAN / LAN, subnet mask
255.255.255.0) will be automatically applied if
no IP address is assigned within 30 seconds
of connecting to the network.
USB 1 x USB Type-A
LCD Panel
Size 1.6”
LCM Display 64 x 128 resolution
LCM Setting 3 x Pushbuttons (Up, Down, Enter)
Switches
Power 1 x on/off switch
IR Learning
VK2200