Kawasaki KDX200 (1989-1994) [46/174] Cooling hoses breather hose inspection

Содержание

Похожие устройства

COOLING SYSTEM 3 11 Wet the top and bottom valve seals with water or coolant to prevent pressure leaks Install the cap on a cooling system pressure tester Watching the pressure gauge pump the tester to build up the test pressure The cap must open at the specified relief pressure the gauge hand flicks down Cooling Hoses Breather Hose Inspection In accordance with the Periodic Maintenance Chart visually inspect the hoses for signs of deterioration Squeeze the hose A hose should not be hard and brittle nor should it be soft or swollen Replace any damaged hose Cooling Hoses Breather Hose Installation Notes Install the cooling hoses or breather hose being careful to follow the preformed bends see Exploded View and Cable Harness Hose Routing in the General Information chapter Avoid sharp bending kinking flattening or twisting Tighten the hose clamps securely 1 Pressure Tester 2 Radiator Cap Radiator Cap Relief Pressure 95 125kPa 0 95 1 25 kg cm2 14 18 psi o Also the cap must hold the relief pressure for at least 6 seconds If the cap cannot hold the pressure or if the relief pressure is too high or too low replace the cap with a new one Filler Neck Inspection Check the radiator filler neck for signs of damage Check the condition of the top and bottom sealing seats in the filler neck They must be smooth and clean for the radiator cap to function properly A Top Sealing Seat B Bottom Sealing Seat A Cooling Hoses B Breather Hose A Cooling Hose B Breather Hose