Похожие устройства

3 6 COOLING SYSTEM Radiator Filler Neck A Cylinder Head B Air Bleeder Bolt 1 Breather Hose 2 Coolant Level Fill the reserve tank up to the FULL mark with coolant and install the cap Tighen the air bleeder bolt Start the engine warm up the engine thoroughly and then stop the engine Remove the left side cover Check the coolant level after the engine cools down If the coolant level is low remove the reserve tank cap and add coolant up to the FULL mark Install the reserve tank cap Check the cooling system for leaks Install the left side cover Cooling System Pressure Testing Any time the system slowly loses coolant inspect for leaks CAUTION oDuring pressure testing do not exceed the pres sure for which the system is designed to work The maximum pressure is 125 kPa 1 25kg cm2 18 psi A Reserve Tank B FULL Mark Check the cooling system for leaks Install the right radiator cap and left side cover Remove the right radiator cover Remove the radiator cap and install a cooling sys tem pressure tester on the radiator filler neck NOTE Air Bleeding Before putting the motorcycle into operation any air trapped in the cooling system must be removed as follows Loosen the air bleeder bolt on the rear of the cylinder head and until the coolant begins to flow out the air bleeder bolt hole that is after all the remaining air has been forced out oWet the adapter cap sealing surfaces with water or coolant to prevent pressure leaks Build up pressure in the system carefully until the pressure reaches 125 kPa 1 25 kg cm2 18 psi Watch the gauge for at least 6 seconds If the pres sure holds steady the cooling system is all right