Graco 24F882 LDM5 [10/34] Setup menus

Graco 24F882 LDM5 [10/34] Setup menus
LDM5 Meter Setup and Operation Instructions
10 312668Z
Setup Menus (FIG. 10)
1. If the display is blank (asleep), wake it up by press-
ing any button on the keypad (F
IG. 10).
2. Press and hold the Total and
Reset buttons simultaneously
for approximately six (6) sec-
onds to enter the Setup
Menus (F
IG. 10).
3.
There are three (3) Setup Menus available, stored in
a preset order.
a. The first screen displayed is the Resettable
Total Menu. When this menu is displayed,
R-TOTAL will blink on the screen (F
IG. 11).
b. Press and hold Reset but-
ton to display Units of
Measure Menu. When
this menu is displayed the
last set Unit of Measure-
ment blinks on the screen
(F
IG. 12).
c. Press and hold Reset button again to display
Calibration Menu. When this menu is displayed
CAL blinks on the screen (F
IG. 13).
The total that is displayed when you leave each
menu is the total that is stored.
F
IG. 10
During the first 4 seconds all segments display.
Then for 2 seconds the software version number
displays.
GAL
QTSPTS
LITERS
R-TOTAL
AUTO
Min. Dispense Volume 0.5 liter (0.13 gal)
Minimum Flow Rate 1.0 l/min. (0.26 gpm)
Maximum Flow Rate 19.0 l/min. (5.00 gpm)
Maximum Working Pressure: 70 bar (1000 PSI)
ti12044a