Graco 24F882 LDM5 [6/34] Installation procedure
![Graco 24F889 LDP5 [6/34] Installation procedure](/views2/1193217/page6/bg6.png)
Installation
6 312668Z
Pressure Relief Procedure
The equipment stays pressurized until pressure is man-
ually relieved. To reduce the risk of serious injury from
pressurized fluid, accidental spray from the dispense
valve, or splashing fluid, follow this Pressure Relief
Procedure when you:
• are instructed to relieve pressure.
• check, clean, or service any system equipment.
• install or clean fluid nozzles or filter.
1. Turn off the power supply to the pump.
2. Trigger the dispense valve into a waste container to
relieve pressure.
3. Open any bleed–type master air valves and fluid
drain valves in the system.
4. Leave the drain valve open until you are ready to
pressurize the system.
Grounding
Proper grounding is an essential part of maintaining a
safe system. The movement of fluids through the dis-
pensing system generates static electricity. Static elec-
tricity can cause fumes to ignite, resulting in explosion
and fire. To reduce the risk of static sparking, ground all
system components per local and national electrical
codes. Refer to user manuals for pump and other sys-
tem components to ground the following:
• Pump: Follow manufacturer’s recommenda-
tions.
• Air and Fluid hoses: Use only grounded
hoses.
• Air compressor: Follow the manufacturer’s
recommendations.
• Fluid supply container: Follow the local code.
To maintain grounding continuity when flushing or
relieving pressure, always hold a metal part of valve
firmly to side of grounded metal pail, then trigger valve.
Pre–Installation Procedure
1. Install the battery. See Replacing the Battery on
page 31.
2. Follow the Pressure Relief Procedure.
3. Close the shut–off valve (B, F
IG. 1, page 5).
4. Ground the hose and reel or console. See
Grounding.
Installation Procedure
If this is an existing installation, go to step 7. Steps 1 - 6
are the Flushing Procedure.
1. Close the fluid shutoff valve (B, F
IG. 3) at each dis-
pense position.
2. Make sure:
• the main fluid outlet valve at the pump is closed,
• the air pressure to the pump motor is adjusted,
• the air valve is open.
3. Slowly open main fluid valve.
Leave a minimum of two engaged threads bare
when using PTFE tape. The bare threads ensure a
ground is maintained.
NOTICE
If this is a new installation or if there is contaminated
fluid in the lines, flush the lines before you install the
metered valve. Contaminated lines could cause the
valve to leak.
F
IG. 3
B
ti12081a
Содержание
- Instructions 1
- Ldm5 standard ldp5 preset electronic metered dispense valves 1
- Models see page 2 1
- Models 2
- Warning 3
- Warnings 3
- Warning 4
- Installation 5
- Mounting bracket 5
- Typical installations 5
- Grounding 6
- Installation procedure 6
- Pre installation procedure 6
- Pressure relief procedure 6
- Connecting hose to meter 7
- Electronic control control 1 and gasket 2 installation 7
- Installing extension and nozzle on meter 8
- Keypad buttons 9
- Ldm5 meter setup and operation instructions 9
- Setup menus 10
- Setup menus fig 10 10
- Resettable total 11
- Units of measurement 11
- Calibration 12
- Dispensing fluid in standard mode 13
- Operation 13
- Viewing totals 14
- Error code 15
- Ldp5 meter setup and operation instructions 16
- Locking and unlocking the trigger 16
- Keypad buttons 17
- Setup menus 17
- Setup menus fig 23 17
- Resettable total 18
- Calibration 19
- Units of measurement 19
- Auto preset amount 20
- Shut off default amount 21
- Dispensing fluid in manual mode 22
- Operation 22
- Dispensing fluid in auto mode 23
- Dispensing fluid in auto mode fig 30 23
- Viewing totals 24
- Error codes 25
- Troubleshooting 26
- Em5 pm5 upgrade kits 29
- Fn part no description qty 29
- Nozzle extension accessory kits fn 26 29
- Part no description 29
- Part no description lubricant type 29
- Part no description psi bar rating 29
- Thermal relief kits page 5 29
- Replacing the battery 31
- Replacing the filter 31
- Replacing the nozzle 31
- Security seal 31
- Service 31
- Technical data 32
- Copyright 2008 graco inc all graco manufacturing locations are registered to iso 9001 www graco com revised may 2016 34
- Graco 5 year meter and valve warranty 34
- Graco headquarters minneapolis international offices belgium china japan korea 34
- Graco inc and subsidiaries p o box 1441 minneapolis mn 55440 1441 usa 34
- Graco information 34
Похожие устройства
- Graco 24F882 LDM5 Технические характеристики
- Graco 24F885 LDM5 Инструкция по эксплуатации
- Graco 24F885 LDM5 Технические характеристики
- Graco 24F887 LDM5 Инструкция по эксплуатации
- Graco 24F887 LDM5 Технические характеристики
- Graco 24F888 LDM5 Инструкция по эксплуатации
- Graco 24F888 LDM5 Технические характеристики
- Graco 24F891 LDM5 Инструкция по эксплуатации
- Graco 24F891 LDM5 Технические характеристики
- Graco 255277 LDP5 Инструкция по эксплуатации
- Graco 255277 LDP5 Технические характеристики
- Graco 256216 LDP5 Инструкция по эксплуатации
- Graco 256216 LDP5 Технические характеристики
- Graco 258694 LDP5 Инструкция по эксплуатации
- Graco 258694 LDP5 Технические характеристики
- Graco 24F883 LDP5 Инструкция по эксплуатации
- Graco 24F883 LDP5 Технические характеристики
- Graco 24F884 LDP5 Инструкция по эксплуатации
- Graco 24F884 LDP5 Технические характеристики
- Graco 24F886 LDP5 Инструкция по эксплуатации