Graco Python XL 3/4" [7/48] Installation

Graco Python XL 5/8
Installation
3A3948B 7
Installation
Grounding
Pump: ground through electrically conductive pneu-
matic and fluid lines.
Pneumatic and fluid lines: use only electrically con-
ductive lines.
Air compressor: follow manufacturer’s recommenda-
tions.
Fluid supply container: follow local code.
Required Accessories
Install the following required accessories in the order
shown in F
IG. 1, using adapters as necessary. See Kits
and Accessories starting on page 41.
Pneumatic Line
Bleed-type master pneumatic valve (D): required
in your system to relieve air/gas trapped between it
and the pneumatic motor when the valve is closed.
Be sure the valve is easily accessible from the
pump and located downstream from the pneu-
matic regulator.
Pump pneumatic regulator (E): to control pump
speed and outlet pressure. Locate it close to the
pump.
Pneumatic line filter (C): removes harmful dirt and
moisture from compressed air/gas supply.
Second bleed-type pneumatic valve (pneumatic
shutoff valve) (B): isolates pneumatic line acces-
sories for servicing. Locate upstream from all other
pneumatic line accessories.
Fluid Line
Fluid filter (Y-Strainer) (included in G): with a 60
mesh (250 micron) stainless steel element to filter
particles from the fluid before in reaches the pump.
Fluid shutoff valve (H): shuts off fluid flow.
Pressure relief valve (J): overload protection.
Flush Before Using Equipment
The equipment was tested with lightweight oil, which is
left in the fluid passages to protect parts. To avoid con-
taminating your fluid with oil, flush the equipment with a
compatible solvent before using the equipment. See
Flush the Equipment, page 12.
If using a flammable gas to drive the motor, to reduce
the risk of fire or explosion, route the exhaust away
from all sources of ignition. See Route Exhaust to
Remote Location on page 9.
NOTE: 3.5% of the exhaust is not recoverable, and
will vent to atmosphere at the pump.
To reduce the risk of injury from ejected ice, do not
operate the motor without a plumbed exhaust line or
muffler installed.
Installation must comply with all local codes and regu-
lations.
The equipment must be grounded to reduce the risk
of static sparking. Static sparking can cause fumes to
ignite or explode. Grounding provides an escape wire
for the electric current.