Graco Therm-O-Flow 20 Инструкция по эксплуатации онлайн [38/108] 168112

Graco Therm-O-Flow 20 Инструкция по эксплуатации онлайн [38/108] 168112
Troubleshooting
Code Code
Code
Description Description
Description
Type Type
Type
Cause Cause
Cause
Solution Solution
Solution
A3MF
AWBCleanFan
Filter
Alarm
Coolinginlet
screenisdirty
Cleaninletscreen.
Verifyaccessoryisratedfor240VAC.
A4 _
HighCurrent
Unit_Zone_
Alarm
Defectiveor
shortedto
groundon
zone
Verifyheaterresistanceandcheckforshortsto
ground.Replaceasnecessary.
A4C#HighCurrent
FanAWB,Unit
_
DeviationFanisdrawing
toomuch
current
Verifythereisnotanairobstructionattheinlet/outlet
ofenclosure.verifynothingispreventingfanrotation.
Replacefanifnecessary.
ReplaceMZLP.A7 _
Unexp.Curr.
Unit_Zone_
AlarmUnexpected
currentowto
zone
Faultyaccessoryheater.Measureresistanceto
groundbetweenheaterleads.
Checkforlooseordisconnectedwiresorplugs.
CheckforblownfusesonMZLP.
Checkheaterresistanceforopencircuit.
Checkforshortsbetweenheaterandground.
A8 _
NoCurrentUnit
_Zone_
Alarm
NoCurrent
Flowtothe
Zone
Verifycableispluggedintozones3–4.Replace
heaterifnecessary.
A8C
AWBNoFan
Current
Alarm
Coolingfan
notworking
Verifyfanispluggedin.Replaceifnecessary.
AM3#HighCurrent
SSRMZLP_
AlarmExcessive
currentow
intheSSR
CheckforshortsinharnesstoSSR.Checkpolarityof
wiringtoSSR.Replaceifnecessary.
AM4#HighCurrent
Contactor
MZLP_
Alarm
Defectiveor
shortedto
groundon
MZLP
Checkforshortsintheharnesstocontactor.Check
thepolaritytocontactor.Replacecontactorif
necessary.
AM8#NoCurrent
Contactor
MZLP_
Alarm
NoCurrent
Flowtothe
Contactor
EnsureharnesstoMZLPisconnected.Ensurewiring
tocontactorissecure.Replacecontactorifnecessary.
SystemisnotproperlyloadedwithcorrectSoftware.
DialnotsetcorrectonMZLP.DuplicateMZLPdial
positions(i.e.1to1,2to2,ect)
CheckallCANconnectionsbetweentheADMand
missingMZLP.
Checkifhardwareexistsonthenetwork.
CAC#CommError
MZLP_
Alarm
Systemnot
respondingto
ADM.
ReplaceMZLPifnecessary.
DialnotsetcorrectonMZLP5.Setto5onboardwith
daughterboard.
EnsureconnectionsbetweentheADMandhardware
aresecure.
CACX
DBNotPresent
UnitA
AlarmDaughter
Boardnot
responding
ReplaceDaughterBoard.
DialnotsetcorrectonMZLP.Setto4onboardwith
daughterboard.
EnsureconnectionsbetweentheADMandhardware
aresecure.
CACY
DBNotPresent
UnitB
AlarmDaughter
Boardnot
responding
ReplaceDaughterBoard.
38334129D