Graco Therm-O-Flow 20 [91/108] Zone upgrade kit installation

Graco Therm-O-Flow 20 [91/108] Zone upgrade kit installation
AccessoriesandKits
12 12
12
Zone Zone
Zone
Upgrade Upgrade
Upgrade
Kit Kit
Kit
Installation Installation
Installation
1.Disconnectplugfrompoweroutletorturnoff
circuitbreakerforincomingpower.
2.Placegroundingwriststrap(7)overyourwrist
andsecureotherendtoagroundedsurface.
3.Setthekit’sMZLP(1)rotaryswitchto“3”ona
primarysystemor“7”onasecondarysystem.
4.Removescrews(B),removeplate(A),and
gasket(C)fromsystem.Usescrews(2)toinstall
MZLP(1)ontosystemasshown.
Note
ThenewMZLP(1)willbereferredtoas
MZLP3,andtheothertwothatcame
withthesystemwillbereferredtoas
MZLP1andMZLP2.
5.Opentheelectricalenclosuredoor.
Note
Donotforcetheelectricalconnection.
Minimalforceisrequiredtoseatthe
connector.Ifresistanceisfelt,stop,and
verifytheconnectororientation.
6.Connectcable(4)toJ3connectoronMZLP2
andJ6connectoronMZLP(1).Removeexisting
powercablefromMZLP2J2andAWBJ5
connector.
7.Connectpowerharness(6)toMZLP2andMZLP
3J2connectorandJ5connectoronAWB.Install
8.SeeInstallHeatedHose
,toconnectaheatedhoseoruidcontroldevice.
9.Toensureyoursystemhasthelatest
software,inserttoken(8)intotheADM.See
UpdateSoftware,page56.