Graco Therm-O-Flow 20 [54/108] Replace transformer

Graco Therm-O-Flow 20 [54/108] Replace transformer
Repair
Replace Replace
Replace
Transformer Transformer
Transformer
SeeFig35,page57.
1.Turnthemainpowerswitchoff.
2.Openelectricalenclosuredoor.
3.Disconnectincomingpowerharness(234)from
topoftransformer(235).
4.Disconnecttransformer(235)outputpower
harnesswires(RCD-W1,-W2,-W3,-W4)from
RCD-1.
5.Disconnecttransformer(235)groundwirefrom
thebackpanelgroundlug.
6.Disconnectthered(+)andblack(-)wireoffan
frompins4and3ofJ7connectoronAWB(205).
DisconnectJ7connectorfromAWB.
7.Cutwireziptiessecuringfanwires.
8.Removeangednuts(N)andtransformer(235)
fromthebackpanel(201).
9.Installtransformer(235)ontomountingstudson
backpanel(201)andsecurewithangednuts
(N).
10.Insertthermalsensorconnectorfromtransformer
(235)ontoJ7connectoronAWB(205).
11.Reconnectred(+)wirefromfanintopin4and
theblack(-)wireintopin3ofJ7connector.
12.Installtransformer(235)groundwireontoground
lugofbackpanel(201).
13.Connecttransformeroutputpowerharness(234)
topowerterminalconnections.Torqueto25–27
in-lbs(2.8–3.1N•m).
Table Table
Table
11 11
11
Transformer Transformer
Transformer
Output Output
Output
Power Power
Power
Harness Harness
Harness
Connections Connections
Connections
Power Power
Power
Harness Harness
Harness
Wires Wires
Wires
RCD RCD
RCD
- -
-
1 1
1
Connections Connections
Connections
RCD-W1
TerminalN
RCD-W2
Terminal5
RCD-W3
Terminal3
RCD-W4
Terminal1
14.Installincomingpowerharness(234)totopof
transformerinvoltageportspeciedonmachine
serialnumberlabel.
15.Verifyallelectricalconnections,includingearth
grounds,arecompeteandtight.Allconnections
andplugsmustbeconnectedpriortoapplying
power.
16.Closetheelectricalcontrolpaneldoor.
17.Applypowertothemachine.Turnonthemain
powerswitch.
18.Restartthesystem.
54334129D