Moxa MD-119-X1 [32/44] Display setup service menu
![Moxa MD-119-X1 [32/44] Display setup service menu](/views2/1200633/page32/bg20.png)
MD-124 HW Manual On-screen Display and Display Configuration
B-16
Main Source, Second Source, Swap Source. The assignment No Function eliminates all hotkey assignments
for the right/left arrows, leaving them (per default) only effective when the OSD Menu is activated.
When selected, a box icon (█) will indicate that the selected function has been activated.
Display Setup: Service Menu
Display-Setup-Service Menu-Type and Serial
This is only available in Full Menu mode.
This menu item reports the display unit’s model and serial number. This information is stored electronically,
on-board. Example: MD-119ABCD12345678: the model number forms the first five numbers, and the remaining
digits form the serial number.
Display-Setup-Service Menu-Firmware Ver
This is only available in Full Menu mode.
This menu item reports the device’s firmware version. Firmware updates may only be undertaken by a Moxa
engineer. If a firmware revision or customization is required, please contact Moxa’s customer support to learn about
our Professional Design Service (PDS).
Example: “V.10 S15”.
Display-Setup-Service Menu-Elapsed Time (Hours)
This is only available in Full Menu mode.
This function reports the total hours the display panel has been running since it was first installed; this is not the
same as how long the display has been powered up: the total time spent displaying an image since installation is
reported, and only time spent actually displaying an image is included. With reference to the device’s MTBF, this
menu item may be used to calculate the remaining life span of the device.
As an example, if the number 452 is displayed, here, then the device has been displaying images for a total of 452
hours.
Display: Input Sources / Dual Image Displays
Display-Source-Single-xxx
This menu item allows users to configure the display to display a single, solitary source input, without any
picture-in-a-picture or picture-by-a-picture configuration.
After navigating to Display/Source, upon selecting Single from the menu offered you will be transferred to a
submenu from which you may then select which signal source should be configured as the sole input signal to be
displayed. A small, square icon ( █ ) will appear next to whichever menu item is selected to indicate the currently
configured signal source.
Whichever source is selected as the single display will automatically be configured as the Main Source. This means
that, should the Swap Source feature be selected, the input source configured through the
Display-Source-Single function will be switched out with whichever composite input signal (Composite 1, 2, or 3)
has been configured as the Second Source. Consequently, because the display controller has been previously
configured for Single mode, the currently configured Main Source image will disappear and be replaced with the
Second Source (which will become the new Main Source). To return the device to its original configuration,
simply select Swap Source once again and the display controller will return to its original display configuration.
Choosing “single” will display only the input signal that has been configured as Main Source.
To change the signal source that is used in single mode, navigate into the submenu as before (i.e., by using the right
arrow to select Single from within the Display/Source menu) and choose which input signal should be prioritized
as the Main Source.
Содержание
- First edition february 2013 1
- Md 119 hardware manual 1
- Www moxa com product 1
- Copyright notice 2
- Disclaimer 2
- Md 119 hardware manual 2
- Technical support contact information 2
- Trademarks 2
- Www moxa com support 2
- Table of contents 3
- Introduction 4
- Md 124 hw manual introduction 5
- Overview 5
- Package checklist 5
- Product features 5
- Display 6
- Environmental limits 6
- Front panel 6
- Md 119 hardware specifications 6
- Md 124 hw manual introduction 6
- Physical characteristics 6
- Power requirements 6
- Serial communication parameters 6
- Serial interface 6
- Serial signals 6
- Standards and certifications 6
- Md 124 hw manual introduction 7
- Warranty 7
- Hardware introduction 8
- Appearance and layout 9
- Md 124 hw manual hardware introduction 9
- Dimensions 10
- Led indicators 10
- Md 124 hw manual hardware introduction 10
- On screen display control buttons 10
- Hardware installation and peripherals 11
- Attention 12
- Installing the md 119 12
- Md 124 hw manual hardware installation and peripherals 12
- Wiring requirements 12
- Attention 13
- Connecting data transmission cables 13
- Connecting power sources 13
- Connecting to a serial device 13
- Grounding the md 119 13
- Md 124 hw manual hardware installation and peripherals 13
- Connecting to computers or laptops 14
- Md 124 hw manual hardware installation and peripherals 14
- Enabling the built in buzzer 15
- Md 124 hw manual hardware installation and peripherals 15
- Regulatory approval statement 16
- On screen display and display configuration 17
- Buttons 18
- Led indicators 18
- On screen display osd controls 18
- Opening the configuration screen 18
- Osd passwords keycode 18
- Md 124 hw manual on screen display and display configuration 19
- Osd filetree legend 19
- Osd menu map 19
- Main group 1 20
- Md 124 hw manual on screen display and display configuration 20
- Main group 2 21
- Md 124 hw manual on screen display and display configuration 21
- Main group 3 22
- Md 124 hw manual on screen display and display configuration 22
- Basic image properties 23
- Display picture brightness 23
- Display picture contrast 23
- Display picture frequency 23
- Display picture phase 23
- Display picture sharpness 23
- Osd menu items explained 23
- Display picture color 24
- Display picture pip pbp adjust h position 24
- Display picture pip pbp adjust pip picture brightness 24
- Display picture pip pbp adjust pip size 24
- Display picture pip pbp adjust v position 24
- Display picture tint 24
- Md 124 hw manual on screen display and display configuration 24
- Picture pip adjustments 24
- Display picture adv settings color temperature xx00k 25
- Display picture pip pbp adjust pip picture color 25
- Display picture pip pbp adjust pip picture contrast 25
- Display picture pip pbp adjust pip picture sharpness 25
- Display picture pip pbp adjust pip picture tint 25
- Md 124 hw manual on screen display and display configuration 25
- Picture advanced settings 25
- Display picture adv settings color temperature user rgb 26
- Display picture adv settings graphic scaling anamorphic 26
- Display picture adv settings graphic scaling fill aspect ratio 26
- Display picture adv settings graphic scaling fill screen 26
- Display picture adv settings graphic scaling one to one 26
- Md 124 hw manual on screen display and display configuration 26
- Display picture adv settings graphic scaling auto 27
- Display picture adv settings horz position 27
- Display picture adv settings rgb calibrate 27
- Display picture adv settings vert position 27
- Display picture swap source 27
- Md 124 hw manual on screen display and display configuration 27
- Swap input sources main to second second to main 27
- Auto setup 28
- Display picture auto setup 28
- Display picture picture info main source 28
- Display picture picture info second source 28
- Display setup osd 28
- Display setup osd settings language 28
- Display setup osd settings osd timeout sec 28
- Display setup osd settings transparency 28
- Image information 28
- Md 124 hw manual on screen display and display configuration 28
- Display setup osd settings full menu 29
- Display setup osd settings osd horz position 29
- Display setup osd settings osd mode full 29
- Display setup osd settings osd mode simplified 29
- Display setup osd settings osd vert position 29
- Md 124 hw manual on screen display and display configuration 29
- Display setup osd settings lock mode normal 30
- Display setup osd settings lock mode password protect 30
- Display setup user settings 30
- Display setup user settings communication 2 wire rs 485 30
- Display setup user settings communication 4 wire rs 485 rs 422 30
- Display setup user settings communication rs 232 30
- Display setup user settings dpms 30
- Md 124 hw manual on screen display and display configuration 30
- Display setup direct access right left arrow hotkeys 31
- Display setup load default factory default 31
- Display setup load default load user default 31
- Display setup load default save user default 31
- Display setup preset defaults 31
- Display setup user settings communication address 31
- Display setup user settings splash screen 31
- Md 124 hw manual on screen display and display configuration 31
- Display input sources dual image displays 32
- Display setup service menu 32
- Display setup service menu elapsed time hours 32
- Display setup service menu firmware ver 32
- Display setup service menu type and serial 32
- Display source single xxx 32
- Md 124 hw manual on screen display and display configuration 32
- Display source pbp xxx 33
- Display source pip xxx 33
- Md 124 hw manual on screen display and display configuration 33
- Display power off 34
- Md 124 hw manual on screen display and display configuration 34
- Power off 34
- Display uart command 35
- Addr address 36
- Attn attention 36
- Command format description 36
- Connecting to the display 36
- Data format 36
- Date rate 36
- Uart command format 36
- Uart software configuration 36
- Cmd message commands and queries 37
- Data data field 37
- Idchk inverse data checksum 37
- Ihchk inverse header checksum 37
- Len data length 37
- Md 119 hw manual display uart command 37
- Downloading files 38
- Md 119 hw manual display uart command 38
- Downloading 39
- Downloading dual rgb file 39
- Md 119 hw manual display uart command 39
- Uploading 39
- Uploading downloading configuration files 39
- Bli brightness control 40
- Dst display state 40
- Man manufacturer id code 40
- Md 119 hw manual display uart command 40
- Osd control command 40
- This command is sent to the unit to request manufacturer id no data shall be sent with this 40
- Md 119 hw manual display uart command 41
- Pot potentiometer control 41
- Snb serial number query 41
- Typ type model number query 41
- Mcc osd control 42
- Md 119 hw manual display uart command 42
- Swi software version query 42
- Ver version number 42
- Function command description acknowledge if enabled 43
- Mcc control command 43
- Md 119 hw manual display uart command 43
- Md 119 hw manual display uart command 44
Похожие устройства
- Moxa MD-119-X1 Технические характеристики
- Moxa MD-124X Инструкция по эксплуатации
- Moxa MD-124X Руководство по аппаратной части
- Moxa MD-124X Технические характеристики
- Moxa MD-124Y Инструкция по эксплуатации
- Moxa MD-124Y Руководство по аппаратной части
- Moxa MD-124Y Технические характеристики
- Moxa MD-124Z Инструкция по эксплуатации
- Moxa MD-124Z Технические характеристики
- Moxa MD-124Z Руководство по аппаратной части
- Moxa MD-219X Инструкция по эксплуатации
- Moxa MD-219X Технические характеристики
- Moxa MD-219X Руководство по аппаратной части
- Moxa MD-219Z Инструкция по эксплуатации
- Moxa MD-219Z Технические характеристики
- Moxa MD-219Z Руководство по аппаратной части
- Moxa MD-219Z-HB Инструкция по эксплуатации
- Moxa MD-219Z-HB Руководство по аппаратной части
- Moxa MD-219Z-HB Технические характеристики
- Moxa MD-224X Инструкция по эксплуатации