D-Link DIS-200G-12PS [138/172] Command default level

D-Link DIS-200G-12PS [138/172] Command default level
DIS-200G Series Gigabit Ethernet Switch CLI Reference Guide
135
no clock summer-time
Parameters
date
Specifies that summer time should start and end on the specified
date of the specified month.
DATE
Specifies the date of the month (1 to 31).
MONTH
Specifies the month (1 to 12).
YEAR
Specifies the start and end years for the summer time data.
HH:MM
Specifies the time (24 hours format ) in hours and minutes.
OFFSET
(Optional) Specifies the number of minutes to add during summer
time. The default value is 60. The range of this offset is 30, 60, 90
and 120.
Default
By default, this option is disabled.
Command Mode
Global Configuration Mode.
Command Default Level
Level: 15.
Usage Guideline
Use this command to automatically switch over to summer time. .
Example
This example shows how to specify that summer time starts on 2:00 a.m. on Jun 16, 2017 and ends on 2:00
a.m. on Dec 31, 2017.
Switch# configure terminal
Switch(config)# clock summer-time date 1 6 2017 2:00 31 12 2017 2:00
Switch(config)#
31-3
clock timezone
This command is used to set the time zone for display purposes. Use the
no
form of this command to revert to
the default setting.
clock timezone {+ | -}
HOURS-OFFSET
[
MINUTES-OFFSET
]
no clock timezone
Parameters
+|-
+: Specifies that time to be added to the UTC.
- : Specifies that time to be subtracted from the UTC.