D-Link DIS-200G-12PS [75/172] Command default level

D-Link DIS-200G-12PS [75/172] Command default level
DIS-200G Series Gigabit Ethernet Switch CLI Reference Guide
72
,
(Optional) Specifies a series of interfaces, or separate a range of
interfaces from a previous range. No spaces are allowed before
and after the comma.
-
(Optional) Specifies a range of interfaces. No spaces are allowed
before and after the hyphen.
Default
None.
Command Mode
EXEC Mode or Any Configuration Mode.
Command Default Level
Level: 1.
Usage Guideline
Use this command to display the loopback detection setting and status.
Example
This example shows how to displays the current loopback detection settings and status.
Switch# show loopback-detection
Loop Detection : Enabled
Interval : 20 seconds
Recover Time : 60 seconds
Interface State Result Time Left (sec)
-------------- -------- ----------------- ---------------
Ethernet1/0/1 Disabled Normal -
Ethernet1/0/2 Disabled Normal -
Ethernet1/0/3 Enabled Loop 120
Ethernet1/0/4 Enabled Loop 115
Port-channel1 Enabled Loop 50
Port-channel2 Disabled Normal -
Switch#
This example shows how to displays the loopback detection status for port 1/0/1.
Switch# show loopback-detection interface Ethernet 1/0/1
Interface State Result Time Left (sec)
-------------- -------- ----------------- ---------------
Ethernet1/0/1 Disabled Normal -
Switch#