AF400 ... AF750 3-pole contactors
200 to 400 kW
AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
Description
AF400 ... AF750 contactors are mainly used for controlling 3-phase motors and power circuits up to
1000 V AC or 600 V DC (2). These contactors are of the block type design with 3 main poles.
control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 48...500 V 50/60 Hz and
24...500 V DC
- can manage large control voltage variations
- reduced panel energy consumption
- very distinct closing and opening
- can withstand short voltage dips and voltages sags (SEMI F47 conditions of use on request).
built-in surge suppression
add-on auxiliary contact blocks for side mounting and a wide range of accessories.
Ordering details
IEC UL/CSA Rated control circuit
voltage
Uc min. ... Uc max.
Auxiliary
contacts
fitted
Type Order code Weight
Pkg
(1 pce)
Rated operational 3-phase
motor
rating
General
use
rating
power current
θ ≤ 40 °C
400 V 690 V 480 V 600 V AC
AC-3 AC-1
kW A hp A V 50/60 Hz V DC kg
200 600 350 550 - 24…60 1 1 AF400-30-11 1SFL577001R6811 (1) 12.000
48…130 48…130 1 1 AF400-30-11 1SFL577001R6911 12.000
100…250 100…250 1 1 AF400-30-11 1SFL577001R7011 12.000
250…500 250…500 1 1 AF400-30-11 1SFL577001R7111 12.000
250 700 400 650 - 24…60 1 1 AF460-30-11 1SFL597001R6811 (1) 12.000
48…130 48…130 1 1 AF460-30-11 1SFL597001R6911 12.000
100…250 100…250 1 1 AF460-30-11 1SFL597001R7011 12.000
250…500 250…500 1 1 AF460-30-11 1SFL597001R7111 12.000
315 800 500 750 - 24…60 1 1 AF580-30-11 1SFL617001R6811 (1) 15.000
48…130 48…130 1 1 AF580-30-11 1SFL617001R6911 15.000
100…250 100…250 1 1 AF580-30-11 1SFL617001R7011 15.000
250…500 250…500 1 1 AF580-30-11 1SFL617001R7111 15.000
400 1050 600 900 - 24…60 1 1 AF750-30-11 1SFL637001R6811 (1) 15.000
48…130 48…130 1 1 AF750-30-11 1SFL637001R6911 15.000
100…250 100…250 1 1 AF750-30-11 1SFL637001R7011 15.000
250…500 250…500 1 1 AF750-30-11 1SFL637001R7111 15.000
(1) The connection polarities indicated close to the coil terminals must be respected: A1 for the positive pole and A2 for the negative pole.
(2) Up to 850 V DC for AF580, AF750.
AF400 ... AF750 are equipped with low voltage inputs for control, for example by a PLC.
Control inputs
1SFC101022V0001
AF460-30-11
1SFC101025V0001
AF750-30-11
Main dimensions mm, inches
63 2.48"
186 7.32"
25
0.98"
22.5
0.89"
11.5
0.45"
268 10.55"
ø 10.5
0.41"
ø 6.5
0.26"
E1626D1
216 8.5"
48.5
1.91"
6
0.24"
E1627D1
278 10.94"
72 2.83"
210 8.27"
40 1.57" 22.5 0.89"
11.5
0.45"
273 10.75"
ø12.5 0.49"ø6.5 0.26"
E1632D
242 9.53"
48.5 1.91" 6 0.24"
E1633D
283 11.14"
AF400, AF460 AF580, AF750
1SFC101013C0201 - Rev. A
5
Time) Time) Time)

Содержание

Скачать