ABB AS09-30-10-26 [55/202] Accessories

ABB ASL09-30-10-81 [55/202] Accessories
B6, B7, BC6, BC7 3 and 4-pole mini contactors
VB6, VB7, VBC6, VBC7 3-pole mini reversing contactors
Accessories
Odering details
For contactors
Auxiliary
contacts
Type Order code
Pkg
qty
Weight
(1 pce)
kg
Front-mounted instantaneous auxiliary contact blocks
(not allowed for mounting on TBC, B6S, B7S, interface contactors) (1)
B6-, B7-40-00, BC6-, BC7-40-00
VB6, VB7, VBC6, VBC7, VB6A, VB7A
VBC6A, VBC7A
1 1 CAF6-11E GJL1201330R0002 10 0.020
2 0 CAF6-20E GJL1201330R0006 10 0.020
0 2 CAF6-02E GJL1201330R0010 10 0.020
B6-, B7-30-10, BC6-, BC7-30-10
VB6, VB7, VBC6, VBC7, VB6A, VB7A
VBC6A, VBC7A
1 1 CAF6-11M GJL1201330R0003 10 0.020
2 0 CAF6-20M GJL1201330R0007 10 0.020
0 2 CAF6-02M GJL1201330R0011 10 0.020
B6-, B7-30-01, BC6-, BC7-30-01
VB6, VB7, VBC6, VBC7, VB6A, VB7A
VBC6A, VBC7A
1 1 CAF6-11N GJL1201330R0004 10 0.020
2 0 CAF6-20N GJL1201330R0008 10 0.020
0 2 CAF6-02N GJL1201330R0012 10 0.020
Side-mounted instantaneous auxiliary contact block (1)
B6-, B7-40-00, BC6-, BC7-40-00 1 1 CA6-11E GJL1201317R0002 10 0.030
B6-, B7-30-10, BC6-, BC7-30-10 1 1 CA6-11M GJL1201317R0003 10 0.030
B6-, B7-30-01, BC6-, BC7-30-01 1 1 CA6-11N GJL1201317R0004 10 0.030
(1) CA6 and CAF6 must not be fitted simultaneously.
For contactors Rated control
circuit voltage Uc
Connection type Type Order code
Pkg
qty
Weight
(1 pce)
V DC kg
Surge suppressors for contactor coils
BC6, BC7 24...60 Cable lug RV-BC6/60 GHV2501902R0002 10 0.005
Flat pin, 2.8 mm RV-BC6-F/60 GHV2501902R0003 10 0.005
50...250 Cable lug RV-BC6/250 GHV2501903R0002 10 0.005
Flat pin, 2.8 mm RV-BC6-F/250 GHV2501903R0003 10 0.010
380 Cable lug RV-BC6/380 GHV2501904R0002 10 0.005
Flat pin, 2.8 mm RV-BC6-F/380 GHV2501904R0003 10 0.010
Note: Mini contactors for AC operation have an integrated protective circuit.
Connecting links with manual motor starters
To connect B..VB.. mini contactor to MS116, MS132
BEA7/132
1SBN080906R1002
10
0.013
To connect B..VB.. mini contactors to MS325
BEA7/325 1SBN080906R1001 10 0.021
Connection sets for reversing contactors
VB6, VB7, VBC6, VBC7, VB6A, VB7A, VBC6A, VBC7A,
cross-section 1.8 mm²
BSM6-30 GJL1201908R0001 10 0.010
Parallel connecting link
B6, B7, BC6, BC7 LP6 GJL1201907R0001 100 0.009
Cover cap, transparent fitting to DIN rail design, sealable
B6, B7, BC6, BC7 LT6-B GJL1201906R0001 10 0.015
Overload relays fitting details (2)
Contactor types Thermal overload relays Electronic overload relays
B6, B7, BC6, BC7 T16 (0.10...16 A) E16DU (0.10...18.9 A)
(2) Direct mounting - No kit required. Ordering details, see overload relays section.
2CDC211012S0010
CAF6-11N
2CDC211007S0010
RV-BC6/250
2CDC211008S0010
CA6-11E-P
2CDC211018S0011
CA6-11E
SST27792R
BSM6-30
2CDC231012F0011
T16
1SBC101635S0201
ABB Motor protection and control - short form catalog | 3/17