ABB AS09-30-10-26 [98/202] Direct on line starters protected by thermal overload relays with af contactors open type version in kit form

ABB ASL09-30-10-81 [98/202] Direct on line starters protected by thermal overload relays with af contactors open type version in kit form
Contactors Thermal overload relays Accessories
IEC
Control voltage
Uc min. ... Uc max.
(1)
Type Order code Setting ranges Type Order code
AC-3, 400 V
Rated
power
Rated
current
kW A
V 50/60 Hz V DC A
4 8.5 24...60 20...60
AF09Z-30-10-21 1SBL136001R2110
7.60...10.0
TF42-10 1SAZ721201R1043
100...250 100...250
AF09-30-10-13 1SBL137001R1310
5.5 11.5 24...60 20...60
AF12Z-30-10-21 1SBL156001R2110
10.0...13.0
TF42-13 1SAZ721201R1045
100...250 100...250
AF12-30-10-13 1SBL157001R1310
7.5 15.5 24...60 20...60
AF16Z-30-10-21 1SBL176001R2110
13.0...16.0
TF42-16 1SAZ721201R1047
100...250 100...250
AF16-30-10-13 1SBL177001R1310
11 22 24...60 20...60
AF26Z-30-00-21 1SBL236001R2100
20.0...24.0
TF42-24 1SAZ721201R1051
100...250 100...250
AF26-30-00-13 1SBL237001R1300
15 29 24...60 20...60
AF30Z-30-00-21 1SBL276001R2100
29.0...35.0
TF42-35 1SAZ721201R1053
100...250 100...250
AF30-30-00-13 1SBL277001R1300
18.5 35 24...60 20...60
AF38Z-30-00-21 1SBL296001R2100
35.0...38.0/40.0
TF42-38 1SAZ721201R1055
100...250 100...250
AF38-30-00-13 1SBL297001R1300
18.5 35 24...60 20...60
AF40-30-00-11 1SBL347001R1100
30.0...40.0
TF65-40 1SAZ811201R1003
100...250 100...250
AF40-30-00-13 1SBL347001R1300
22 41 24…60 20…60
AF52-30-00-11 1SBL367001R1100
36.00…47.0
TF65-47 1SAZ811201R1004
100-250 100-250
AF52-30-00-13 1SBL367001R1300
30 55 24…60 20…60
AF65-30-00-11 1SBL387001R1100
50.0…60.0
TF65-60 1SAZ811201R1006
100-250 100-250
AF65-30-00-13 1SBL387001R1300
37 66 24…60 20…60
AF80-30-00-11 1SBL397001R1100
57.0…68.0
TF96-68 1SAZ911201R1003
100-250 100-250
AF80-30-00-13 1SBL397001R1300
45 80 24…60 20…60
AF96-30-00-11 1SBL407001R1100
75.0..87.0
TF96-87 1SAZ911201R1005
100-250 100-250
AF96-30-00-13 1SBL407001R1300
55 97 24…60 20…60
AF116-30-11-11 1SFL427001R1111
80…110
TF140DU-110 1SAZ431201R1002
100-250 100-250
AF116-30-11-13 1SFL427001R1311
75 132 24…60 20…60
AF140-30-11-11 1SFL447001R1111
100…135
TF140DU-135 1SAZ431201R1003
100-250 100-250
AF140-30-11-13 1SFL447001R1311
90 160 24…60 20…60
AF190-30-11-11 1SFL487002R1111
130…175
TA200DU-175 1SAZ421201R1005
100-250 100-250
AF190-30-11-13 1SFL487002R1311
110 195 24…60 20…60
AF205-30-11-11 1SFL527002R1111
150…200
TA200DU-200 1SAZ421201R1006
100-250 100-250
AF205-30-11-13 1SFL527002R1311
(1) For other control voltages, see "Voltage code table".
Note : for rated power above 110 kW, refer to "Starters protected by electronic overload relays".