ABB AS09-30-10-26 [33/202] Main accessories ms5100 mo5100 manual motor starters

ABB ASL09-30-10-81 [33/202] Main accessories ms5100 mo5100 manual motor starters
2CDC131051C0201a
ABB Motor protection and control - short form catalog | 2/25
Main accessories
MS5100, MO5100 manual motor starters
Description
Manual motor starters can be equipped with auxiliary contacts, undervoltage release and shunt trips.
Undervoltage release are used for remote tripping of the manual motor starter especially for emergency
stop circuits. Shunt trips release the MMS used for remote tripping.
For this manual motor starter range we also offer key lock solutions for customer applications.
Ordering details
Suitable
for
Auxiliary
con-
tacts
N.O.
Auxiliary
con-
tacts
N.C.
Description Type Order code Pkg
qty
Weight
(1 pce)
pcs kg
Auxiliary contacts - mountable inside the breaker on the left slot (cabled version)
MS5100,
MO5100
Changeover AUX-C 1Q+1SY 250V AC 1SDA066431R1 2 0.06
Changeover AUX-C 2Q+1SY 250V AC 1SDA066433R1 3 0.09
MS5100 Changeover AUX-C 2Q+2SY+1SA 250V AC 1SDA066438R1 5 0.15
Changeover AUX-C 3Q+1SY 250V AC 1SDA066434R1 4 0.12
Changeover AUX-C 3Q+2SY 250V AC 1SDA066436R1 5 0.15
MO5100 Changeover AUX-C 1Q+1SY 24V DC 1SDA066446R1 2 0.06
Suitable
for
Rated
control
supply
voltage
Description Type Order code Pkg
qty
Weight
(1 pce)
V pcs kg
Shunt trips units - mountable inside the breaker on the left slot (cabled version)
MS5100,
MO5100
Normally NON
energized
SOR-C 12V DC 1SDA066321R1 1 0.14
Normally NON
energized
SOR-C 24-30V AC/DC 1SDA066322R1 1 0.14
Normally NON
energized
SOR-C 48-60V AC/DC 1SDA066323R1 1 0.14
Normally NON
energized
SOR-C 110-127V AC / 110-125V DC 1SDA066324R1 1 0.14
Normally NON
energized
SOR-C 220-240V AC / 220-250V DC 1SDA066325R1 1 0.14
Normally NON
energized
SOR-C 380-440V AC 1SDA066326R1 1 0.14
Normally NON
energized
SOR-C 480-525V AC 1SDA066327R1 1 0.14
Undervoltages releases - mountable inside the breaker on the left slot (cabled version)
MS5100,
MO5100
Normally energized UVR-C 24-30V AC/DC 1SDA066396R1 1 0.14
Normally energized UVR-C 48V AC/DC 1SDA060965R1 1 0.14
Normally energized UVR-C 60V AC/DC 1SDA066397R1 1 0.14
Normally energized UVR-C 110-127V AC / 110-125V DC 1SDA066398R1 1 0.14
Normally energized UVR-C 220-240V AC / 220-250V DC 1SDA066399R1 1 0.14
Normally energized UVR-C 380-440V AC 1SDA066400R1 1 0.14
Normally energized UVR-C 480-525V AC 1SDA066401R1 1 0.14
Suitable
for
Description Type Order code Pkg
qty
Weight
(1 pce)
pcs kg
Key locks
MS5100 Key lock on the circuit breaker,
different keys, removable in open
position
KLC Ronis
1)
1SDA066599R1 1 NA
MO5100 Key lock on the circuit breaker,
different keys, removable in open
position
KLC Ronis
1)
1SDA066593R1 1 NA
1)
UL Listed
XT AUX-Con cavi-01
AUX-C
XT SOR-Con cavi-01
SOR-C
1SDC210C86F0001
KLC Ronis
2
Time) Time) Time)

Содержание

Скачать