ABB AS09-30-10-26 [123/202] Af1250 af2650 3 pole contactors 475 to 560 kw and 1260 to 2650 a ac 1 ac dc operated with 1 n o 1 n c auxiliary contacts

ABB ASL09-30-10-81 [123/202] Af1250 af2650 3 pole contactors 475 to 560 kw and 1260 to 2650 a ac 1 ac dc operated with 1 n o 1 n c auxiliary contacts
1SFC101094C0201 - Rev. A
AF1250 ... AF2650 are equipped with low voltage inputs for control, for example by a PLC
Control inputs
AF1350, AF1650, AF2050 AF2650
A
392 mm / 15.43" 422 mm / 16.61"
B
47 mm / 1.85" 53 mm / 2.09"
C
10 mm / 0.39" 25 mm / 0.98"
AF1250 ... AF2650 3-pole contactors
475 to 560 kW and 1260 to 2650 A AC-1
AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
Description
AF1250 ... AF2050 contactors are mainly used for controlling power circuits up to 1000 V AC or 850 V DC,
AF2650 for controlling power up to 1000 V AC. These contactors are of the block type design with 3 main
poles.
– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC)
- only 4 coils for AF1250 to cover control voltages between 48...500 V 50/60 Hz and 24...500 V DC
- only 1 coil for AF1350 ... AF2650 to cover control voltages between 100...250 V 50/60 Hz and
100...250 V DC
- can manage large control voltage variations
- reduced panel energy consumption
- very distinct closing and opening
- can withstand short voltage dips and voltages sags (SEMI F47 conditions of use on request).
– built-in surge suppression
– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
Ordering details
IEC UL/CSA Rated control circuit
voltage
Uc
(1)
Auxiliary
contacts
fitted
Type Order code Weight
Pkg
(1 pce)
Rated operational 3-phase
motor
rating
General
use
rating
power current
θ ≤ 40 °C
400 V 690 V 480 V 600 V AC
AC-3 AC-1 (2)
kW A hp A V 50/60 Hz V DC kg
- 1260 - 1210 - 24…60 1 1 AF1250-30-11 1SFL647001R6811 (1) 16.000
48…130 48…130 1 1 AF1250-30-11 1SFL647001R6911 16.000
100…250 100…250 1 1 AF1250-30-11 1SFL647001R7011 16.000
250…500 250…500 1 1 AF1250-30-11 1SFL647001R7111 16.000
475 1350 800 1350 100…250 100…250 1 1 AF1350-30-11 1SFL657001R7011 34.000
560 1650 900 1650 100…250 100…250 1 1 AF1650-30-11 1SFL677001R7011 35.000
- 2050 - 2100 100…250 100…250 1 1 AF2050-30-11 1SFL707001R7011 35.000
- 2650 - 2700 100...250 100...250 1 1 AF2650-30-11 1SFL667001R7011 45.000
(1) The connection polarities indicated close to the coil terminals must be respected: A1 for the positive pole and A2 for the negative pole.
(2) AF2650: Maximum operational voltage = 1000 V according to UL / CSA.
Main dimensions mm, inches
50 1.97"
72 2.83"
72 2.83"
210 8.27"
344 13.54"
313 12.32"
263 10.35"
72 2.83"
ø 7 0.28
"
ø7 0.28"
27
1SFC101124F0001
249 9.8"
242 9.53"
46.5
8 0.31"
18.3"
1SFC101125F0001
40
1.57"
17 0.67"
0.51"
ø 13
0.51"
13
30 1.18"
10 0.39"
40
1.57"
AF2650
40
1.57"
40
1.57"
17
0.67"
ø 13
0.51"
136 5.35"136 5.35"
80 136 5.35"
ø 9 0.35"
B
438 17.24"
A
312 12.3"
C
244 9.61"
3.15"
101
3.98"
40 1.57"
27
13 0.51"
30 1.18"
17 0.67"
10 0.39"
1.06"
AF1350, AF1650
AF2050
AF1250 AF1350, AF1650, AF2050, AF2650
AF1250-30-11
1SFC101027V0001
1SFC101031V0001
AF2650-30-11
ABB Motor protection and control - short form catalog | 5/47
5
Time) Time) Time)

Содержание