Delta Electronics VFD015CB23A-21M Руководство по эксплуатации онлайн [195/363] 460054

Delta Electronics VFD037CB43A-20 Руководство по эксплуатации онлайн [195/363] 460064
Chapter 11 Description of Parameter Settings|C200 Series
11-96
230V
Pr.06-55=1
Pr.06-55=0 or 2
(50: UL open-type)
(40:UL type1 or open type_size by size)
100
110
90
80
70
50
2 56789101112131415
Fc
(kHz)
R
a
ti
o
(
%
)
VFD004~037CB23A
VFD004~022CB21A
60
40
4
3
230V
Pr.06-55=0 or 2
(40: UL open-type)
(30: UL type1 or open type_size by size)
100
110
90
80
70
50
2 56789101112131415
Fc
(kHz)
R
a
ti
o
(
%
)
VFD004~037CB23A
VFD004~022CB21A
60
40
4
3
NOTE
The mounting clearances stated in the figure is for installing the drive in
an open area. To install the drive in a confined space (such as cabinet
or electric box), please follow the following three rules: (1) Keep the
minimum mounting clearances. (2) Install a ventilation equipment or an
air conditioner to keep surrounding temperature lower than operation
temperature. (3) Refer to parameter setting and set up Pr. 00-16,
Pr.00-17, and Pr. 06-55.
The following table shows heat dissipation and the required air volume
when installing a single drive in a confined space. When installing
multiple drives, the required air volume shall be multiplied by the
number the drives.
Refer to the chart (Air flow rate for cooling) for ventilation equipment
design and selection.
Refer to the chart (Power dissipation) for air conditioner design and
selection.
Minimum mounting clearances:
Frame A (mm) B (mm) C (mm) D (mm)
A~C 60 30 10 0
Air flow rate for cooling Power Dissipation
Model No.
Flow Rate
(cfm)
Flow Rate
(m
3
/hr)
Loss External
(Heat sink)
Internal To ta l
VFD004CB21A-20/-21/-21M
- -
16 20 36
VFD007CB21A-20/-21/-21M
- -
32 39 72
VFD015CB21A-20/-21/-21M 15 26 60 52 112
VFD022CB21A-20/-21/-21M 15 26 85 69 154
VFD004CB23A-20/-21/-21M
- -
21 17 37
VFD007CB23A-20/-21/-21M
- -
35 26 61
VFD015CB23A-20/-21/-21M 15 26 56 32 89
VFD022CB23A-20/-21/-21M 15 26 82 34 116
VFD037CB23A-20/-21/-21M 15 26 118 43 161
VFD007CB43A-20/-21/-21M - - 35 24 59
VFD015CB43A-20/-21/-21M - - 47 27 74
VFD022CB43A-20/-21/-21M 15 26 75 30 105
VFD037CB43A-20/-21/-21M 15 26 110 33 143
VFD040CB43A-20/-21/-21M 15 26 126 34 160
VFD055CB43A-20/-21/-21M 15 26 145 37 181
VFD075CB43A-20/-21/-21M 24 41 212 83 295
The required airflow shown in chart is for installing one
The heat dissipation shown in the chart is for

Содержание

Скачать