Emotron CDU/CDX 48-008 [39/82] Emotron dsv 5445 5444

Emotron CDU/CDX 48-008 [39/82] Emotron dsv 5445 5444
EMOTRON DSV 5445/5444
21.04.09 Emotron
Page 39
Adr. Variable in FU-Control Remarks TUDY/X TUDZ
B30 password low V Attention: Changing the value blocks the program /
FUC!
0 0
B32 password high V Attention: Changing the value blocks the program /
FUC!
0 0
B34 version of program
V TUDY / Z...capable software has an index of min. 60!
min. 60 min. 65
B36 actually overload
V Diagnostic cell to determine the cabin loading in %.
0...100 0...100
D2A set point torque load V Diagnostic 's-value: See LAST7TZ.TXT / HTM for
explanation
0...2500 0...2500
D2C actual torque load V Diagnostic 's-value: See LAST7TZ.TXT / HTM for
explanation
0...2500 0...2500
D2E maximum torque load V Diagnostic 's-value: See LAST7TZ.TXT / HTM for
explanation
max. 3473 max. 4048
E00 Vi Inspection run
V Enter speed in m/s, see E2
(FU-Control in mm/s)
Value range: 0.0010 - 1.0000
0.30 0.30
E02 V3 Fast stage
V Enter speed in m/s, see E3
(FU-Control in mm/s)
Only for LIFT7TZ with analogue setpoint setting.
Scales analogue setpoint 10V = V3
Value range: 0.3000 - 6.0000
0.990
1.60
E04 V2 Intermediate. stage
V Enter speed in m/s, see E4
(FU-Control in mm/s)
Value range: 0.1000 - 5.0000
0.750
0.80
E06 V1 Low stage
V Enter speed in m/s, see E5
(FU-Control in mm/s)
Value range: 0.0100 - 4.0000
0.50 0.60
E08 Ve drive-in stage
V Enter speed in m/s, see E6
(FU-Control in mm/s)
Value range: 0.0050 - 0.5000
0.05 0.025
E0A Vn adjust stage
V Enter speed in m/s, see E7
(FU-Control in mm/s)
Value range: 0.0010 - 0.2000
0.010 0.002
E0C Direction of rotation
V For E0C = 0 24 V-level = UP and 0 V-level =
DOWN. For E0C = 255 24 V-level = UP and 24 V-
level = DOWN. For DCP-10SZ, ACP variants and
LIFT9SZ always leave at 255 (a fixed choice of
direction is permanently possible there using 'low'=0V
or 'high'=24V at input 'E8’).
255 255
E0E
max. acc. of vi Linear section of the ramp during inspection-
mode (fixed in the factory).
30 30
E10
Linear ramp normalst. Linear section of the ramp during emergency
(fixed in the factory).
20 200
E12 Start clearance run
V If speed is less than the set value (m/s), then output
A1 is set. At speeds less than the set value, the lift
will stop at the next levelling pulse (only LIFT7SZ/TZ).
(FU-Control in mm/s), value range: 0.003 - 7.000.
Remark: Cell 0E12 controls the switchover point from
'I-gain stop' (0E1C) and the 'I-gain run new' (0E1E) for
virtual load measurement for gearless/EPM. It is only
permitted with gearless to set 0E12 smaller than 'Ve'
(prevents I-switchback to value 0E1C).
0.70
Value
serves here
to mask the
level signal
only with
older prog.
LIFT7SZ,
3SZ, 9SZ
and 10SZ
0.20
Value
serves the
switch-
back to the
I-gain at
stop. For
older DCP-
progr.: 0.50