CHV190 series special inverter for crane
- 137 -
Response
PKW1PKW2PKW3PKW4 CW PZD2 PZD3 PZD12
00010004000050 xx
···
···
xxxxxxxxxx xxxx
0001: Response (Parameter values
refreshed)
00
Example for PZD:
Transmission of PZD area is achieved through inverter function code; please refer to
relevant INVT inverter user manual to know relevant function code.
Example 1: Read process data of inverter
Inverter parameter selects "8: Run frequency" as PZD3 to transmit which can be achieved
by setting Pd.14 as 8. This operation is mandatory until the parameter is instead of others.
Request (From master to inverter):
PKW1
PKW2
PKW3
PKW4
CW PZD2
PZD3
PZD12
Response
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
00
0A
xx
xx
Example 2: Write process data into inverter
Inverter parameter selects "2: Traction given" from PZD3 which can be achieved by setting
Pd.03 as 2. In each request frame, parameters will use PZD3 to update until re-select a
parameter.
Request (From master to converter):
PKW1
PKW2
PKW3
PKW4
CW PZD2
PZD3
PZD12
Response
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
00
00
xx
xx
In each request frame contents of PZD3 are given by traction until re-select a parameter.
7.5.5 Fault information
CH-PA01 module is equipped with three fault display LEDs as shown is figure 7.27. The
roles of these LEDs are as follows:
Figure 7.27 Fault display LEDS