Invt CHV190-5R5G-4 [166/242] Appendix b application mode description

Invt CHV190-315G-4 [166/242] Appendix b application mode description
CHV190 series special inverter for crane
- 165 -
APPENDIX B APPLICATION MODE DESCRIPTION
B.0 General Application Mode
General application mode wiring diagram is as follows:
If set P0.11=0, general mode is valid, I/O signal settings and functions are set as default.
General application mode parameter settings are as follows:
Function code
Name Selection
Description
P0.01 Run command source 1
Terminal command
channel (LED flashing)
P0.02
Speed command
selection
0 Keypad settings
P5.01 S4, S5 input type 0 ON/OFF input
P5.02 S1 terminal function 1 Forward (FWD)
P5.03 S2 terminal function 2 Reverse (REV)
P5.04 S3 terminal function 6 Fault reset (RET)
P6.04
Relay 1 output
selections
4 Fault output
P6.05
Relay 2 output
selections
1 Motor running
P6.07 AO1 output selection 0 Running frequency
P6.08 AO2 output selection 1 Setting frequency
B.1 Operating Lever Mode
Operating lever mode wiring diagram is as follows:

Содержание