General Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with
relative humidity at 0 % to 90 %.
Extended specifications are available at www.Fluke.com.
Maximum voltage between any
terminal and earth ground.......................... 600 V
Surge Protection ......................................... 6 kV peak per IEC 61010-1600V CAT III,
Pollution Degree 2
Display ......................................................... Digital: 6,000 counts, updates 4/sec
...................................................................... Bar Graph: 33 segments, updates 32/sec
Temperature ................................................ Operating: -10 °C to + 50 °C
Storage: -40 °C to + 60 °C
Temperature Coefficient............................. 0.1 x (specified accuracy)/°C (<18 °C or >28 °C)
Operating Altitude....................................... 2,000 meters
Battery .......................................................... 9 Volt Alkaline, NEDA 1604A / IEC 6LR61
Battery Life .................................................. Alkaline: 400 hours typical, without backlight
Safety Compliances.................................... Complies with ANSI/ISA 82.02.01 (61010-1) 2004,
CAN/CSA-C22.2 No 61010-1-04, UL 6101B (2003) and
IEC/EN 61010-1 2
nd
Edition for measurement Category III,
600 V, Pollution Degree 2, EMC EN61326-1
Certifications............................................... UL,
P, CSA, TÜV, ;
(N10140), VDE
Содержание
- True rms multimeter users manual 1
- Limited warranty and limitation of liability 2
- Contacting fluke 3
- Introduction 3
- True rms multimeter 3
- Unsafe voltage 3
- Safety information 4
- Users manual 4
- True rms multimeter safety information 5
- Display 6
- Users manual 6
- True rms multimeter display 7
- Terminals 8
- Users manual 8
- Rotary switch positions 9
- True rms multimeter rotary switch positions 9
- Backlight 10
- Battery saver sleep mode 10
- Display hold 10
- Manual and autoranging 10
- Min max avg recording mode 10
- Users manual 10
- Making basic measurements 11
- Power up options 11
- True rms multimeter power up options 11
- Measuring resistance 12
- Testing for continuity 12
- Users manual 12
- Measuring ac and dc millivolts 13
- Measuring ac and dc voltage 13
- True rms multimeter making basic measurements 13
- Using auto volts selection 13
- Control module 14
- Flame sensor probe 14
- Measuring ac and dc current 14
- Users manual 14
- Measuring capacitance 15
- Measuring temperature 15
- Making low impedance capacitance measurements 16
- Measuring frequency 16
- Users manual 16
- Measuring current above 600 a 17
- Testing diodes 17
- True rms multimeter making low impedance capacitance measurements 17
- Maintenance 18
- Replacing the battery 18
- Users manual 18
- Using the bargraph 18
- Cleaning 19
- True rms multimeter cleaning 19
- General specifications 20
- Users manual 20
- True rms multimeter general specifications 21
- Users manual 22
- True rms multimeter general specifications 23
- Users manual 24
Похожие устройства
- Fluke FLK-117 Инструкция по эксплуатации
- Fluke FLK-117 Технические характеристики
- Fluke FLK-117 Расширенная инструкция
- Fluke FLK-1577 Инструкция по эксплуатации
- Fluke FLK-1577 Технические характеристики
- Fluke FLK-1577 Расширенная инструкция
- Fluke FLK-1587FC Инструкция по эксплуатации
- Fluke FLK-1587FC Расширенная инструкция
- Fluke FLK-1587FC Технические характеристики
- Fluke FLK-175 Инструкция по эксплуатации
- Fluke FLK-175 Технические характеристики
- Fluke FLK-175 Расширенная инструкция
- Fluke FLK-177 Инструкция по эксплуатации
- Fluke FLK-177 Технические характеристики
- Fluke FLK-177 Расширенная инструкция
- Fluke FLK-179 Инструкция по эксплуатации
- Fluke FLK-179 Технические характеристики
- Fluke FLK-179 Расширенная инструкция
- Fluke FLK-233 Инструкция по эксплуатации
- Fluke FLK-233 Технические характеристики