Daikin ACEF4AV1-H [26/64] Procedure

Daikin ACEF4AV1-H [26/64] Procedure
Cleaning of Prefilter and Ionizer SiE-64
20 Maintenance
1.2 Ionizer
1.2.1 How to Clean the Ionizer
If (see page 7) on the front panel begins to flash, clean the ionizer.
Procedure 1. Stop the unit and remove the power cabel from its socket.
2. Remove the front panel.
See page 11.
3. Remove the ion filter (roll) case.
Hold the ion filter (roll) case by the left and right side handles, and lift upwards and out.
4. Clean the ionizer.
Wipe the electrode plates and adjacent plastic parts with a soft cloth moistened with water or a wet tissue.
For stubborn dirt, detach the ion filter roll and wash with a neutral household detergent or soak and wipe
with a piece of cloth or soft brush. Thoroughly rinse off all detergent and dry in a dark place.
Note: When cleaning the ionizer, always wear rubber gloves to prevent direct contact with the ionizing wires.
Be careful not to break the ionizing wires. If they should break, you can obtain replacements from your
supplier. If the unit is used with broken ionizing wires, the Clean Ionizer lamp will flash constantly. After
cleaning, dry the ionizer thoroughly. Usig the air cleaner with the ionizer still wet can damage the unit.
Si-64.book Page 20 Monday, June 18, 2001 2:57 PM