Daikin FXDQ63SPV1 [21/40] Specifications

Daikin FXDQ63SPV1 [21/40] Specifications
Specifications
39 40
VRV Indoor Units
Ceiling Mounted Cassette (Double Flow) Type
Ceiling Mounted Cassette Corner Type
FXKQ25MAVE
9,600
2,400
Galvanised steel plate
183/150
FXKQ32MAVE
12,300
3,100
FXKQ40MAVE
15,400
3,900
FXKQ63MAVE
2.8 3.6 4.5
7.1
24,200
6,100
216/166 300/250
11/9 13/10 18/15
215
X
1,110
X
710
31
6.4
12.7
VP25 (External Dia, 32/Internal Dia, 25)
BYK45FJW1
White (10Y9/0.5)
70
X
1,240
X
800
8.5
215
X
1,310
X
710
34
9.5
15.9
BYK71FJW1
70
X
1,440
X
800
9.5
40/35 42/36 44/39
1-phase, 220-240 V/220 V, 50/60 Hz
Note: Specifications are based on the following conditions;
Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m
.
Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
(See Engineering Data Book for details.)
Sound level: (FXCQ-M) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
(FXKQ-MA) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
2,800
10,900
3.2
3,400
13,600
4.0
4,300
17,100
5.0
0.076
0.056
6,900
27,300
8.0
0.105
0.085
0.066
0.046
m
3
/min
mm
kg
mm
mm
kg
kcal/h
Btu/h
kcal/h
Btu/h
kW
kW
kW
Liquid (Flare)
Gas (Flare)
Drain
Model
Colour
Dimensions(H×W×D)
Weight
Power consumption
Casing
Sound level (H/L)
Dimensions (H×W×D)
Machine weight
Piping
connections
Panel
(Option)
Power supply
Heating capacity
Cooling capacity
MODEL
Cooling
Heating
kW
240 V
dB(A)
Airflow rate (H/L)
/s
FXCQ20MVE FXCQ25MVE
FXCQ32MVE
FXCQ40MVE
FXCQ50MVE
FXCQ63MVE FXCQ80MVE
FXCQ125MVE
1-phase, 220-240 V/220 V, 50/60 Hz
1,900 2,400 3,100 3,900 4,800 6,100 7,700 12,000
7,500 9,600 12,300 15,400 19,100 24,200 30,700 47,800
2.2 2.8 3.6 4.5 5.6 7.1 9.0 14.0
2,200
8,500
2.5
0.077
0.044
2,800
10,900
3.2
3,400
13,600
4.0
4,300
17,100
5.0
5,400
21,500
6.3
6,900
27,300
8.0
0.106
0.126
8,600
34,100
10.0
0.209
0.176
13,800
54,600
16.0
0.256
0.223
Galvanised steel plate
116/83 150/108 200/150 275/216 433/350 550/416
7/5 9/6.5 12/9 16.5/13 26/21 33/25
34/29 36/30 37/32 39/34 41/36 46/40
305×775×600
305×990×600
305×1,175×600
305×1,665×600
26.0 31.0 32.0 35.0 47.0 48.0
6.4 9.5
12.7 15.9
VP25 (External Dia, 32/Internal Dia, 25)
BYBC32G-W1 BYBC50G-W1
BYBC63G-W1
BYBC125G-W1
White (10Y9/0.5)
53×1,030×680 53×1,245×680
53×1,430×680
53×1,920×680
8.0 8.5 9.5 12.0
0.092
0.059
0.130
0.097
m
3
/min
dB(A)
mm
kg
mm
mm
kg
kcal/h
Btu/h
kW
kcal/h
Btu/h
kW
kW
kW
Liquid (Flare)
Gas (Flare)
Drain
Model
Colour
Dimensions(H×W×D)
Weight
Power consumption
Casing
Sound level (H/L)
Dimensions (H×W×D)
Machine weight
Piping
connections
Panel
(Option)
Power supply
Heating capacity
Cooling capacity
MODEL
Cooling
Heating
Airflow rate (H/L)
/s
240 V
Slim Ceiling Mounted Duct Type (Standard Series)
Note: Specifications are based on the following conditions;
Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are
normally somewhat higher as a result of ambient conditions.
1 : Values are based on the following conditions: FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure of 15 Pa.
2 : External static pressure is changeable to set by the remote controller. This pressure means "High static pressure - Standard". (Factory setting is
10 Pa for FXDQ-PB models and 15 Pa for FXDQ-NB models.)
3 :
The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).
Slim Ceiling Mounted Duct Type (Compact Series)
Note: Specifications are based on the following conditions;
Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 5.0 m, Level difference: 0 m.
Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 5.0 m, Level difference: 0 m.
Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are
normally somewhat higher as a result of ambient conditions.
1 : Values are based on the following conditions: FXDQ20-32SP: external static pressure of 10 Pa; FXDQ40-63SP: external static pressure of 20 Pa.
2 : External static pressure is changeable to set by the remote controller. This pressure means “High static pressure - Standard”. (Factorysetting is 10
Pa for FXDQ20-32SP models and 20 Pa for FXDQ40-63SP models.)
3 :
The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).
FXDQ20PBVE FXDQ25PBVE FXDQ32PBVE FXDQ40NBVE FXDQ50NBVE FXDQ63NBVE
2 2
Galvanised steel plate
1-phase, 220-240 V/220 V, 50/60 Hz
1,900
7,500
2.2
2,200
8,500
2.5
2,400
9,600
2.8
2,800
10,900
3.2
3,100
12,300
3.6
3,400
13,600
4.0
0.089
0.070
3,900
15,400
4.5
4,300
17,100
5.0
0.160
0.147
4,800
19,100
5.6
5,400
21,500
6.3
0.165
0.152
6,100
24,200
7.1
6,900
27,300
8.0
0.181
0.168
0.086
0.067
133/120/106
8.0/7.2/6.4
30-10
175/158/141
10.5/9.5/8.5
208/183/166
12.5/11.0/10.0
44-15
33/30/27
61/58/55
275/241/216
16.5/14.5/13.0
28/26/23
56/54/51
200×700×620 200×900×620 200×1,100×620
23 27 28
VP20 (External Dia, 26/Internal Dia, 20)
31
9.5
15.9
28/26/24
56/54/52
30/28/26
58/56/54
33/31/29
61/59/57
m
3
/min
Pa
dB(A)
dB(A)
mm
kg
mm
kcal/h
Btu/h
kW
kcal/h
Btu/h
kW
kW
kW
Liquid (Flare)
Gas (Flare)
Drain
Casing
Dimensions (H×W×D)
Machine weight
Piping
connections
Power supply
Heating capacity
Cooling capacity
MODEL
Cooling
Heating
External static pressure
Sound level (HH/H/L)
Sound power (HH/H/L)
Airflow rate (HH/H/L)
/s
Power consumption
1
6.4
12.7
1 3
FXDQ20SPV1 FXDQ25SPV1 FXDQ32SPV1 FXDQ40SPV1 FXDQ50SPV1 FXDQ63SPV1
2
Galvanised steel plate
1-phase, 220-240 V, 50 Hz
1,900
7,500
2.2
2,200
8,500
2.5
0.072
0.056
2,400
9,600
2.8
2,800
10,900
3.2
0.075
0.059
3,100
12,300
3.6
3,400
13,600
4.0
0.078
0.062
3,900
15,400
4.5
4,300
17,100
5.0
0.180
0.152
4,800
19,100
5.6
5,400
21,500
6.3
0.180
0.152
6,100
24,200
7.1
6,900
27,300
8.0
0.196
0.168
150/133/117
9.0/8.0/7.0
30-10
145/127/108
8.7/7.6/6.5
167/150/133
10.0/9.0/8.0
2
250/217/175
15.0/13.0/10.5
50-20
35/33/31
63/61/59
200×900×450
20
2
33/31/29
61/59/57
200×700×450
17
VP20 (External Dia, 26/Internal Dia, 20)
34/32/30
62/60/58
m
3
/min
Pa
dB(A)
dB(A)
mm
kg
mm
kcal/h
Btu/h
kW
kcal/h
Btu/h
kW
kW
kW
Liquid (Flare)
Gas (Flare)
Drain
Casing
Dimensions (H×W×D)
Machine weight
Piping
connections
Power supply
Heating capacity
Cooling capacity
MODEL
Cooling
Heating
External static pressure
Sound level (HH/H/L)
Sound power (HH/H/L)
Airflow rate (HH/H/L)
/s
Power consumption
1
6.4
12.7
333/267/208
20.0/16.0/12.5
40-20
37/35/33
65/63/61
200×1,100×450
23
9.5
15.9
1
3
700 mm width type
900/1,100 mm
width type