Daikin FXDQ63SPV1 [9/40] Horizontal flow airflow block

Daikin FXDQ25SPV1 [9/40] Horizontal flow airflow block
15 16
Indoor Unit Lineup
VRV Indoor Units
If people do not return, the
air conditioner will raise the
temperature 1℃ every 30
minutes and then operate
at 30℃.
If people do not return, the
air conditioner will lower
the temperature 1°C every
30 minutes and then
operate at 16°C.
The system automatically saves energy by
detecting whether or not the room is
occupied. The set temperature is shifted
automatically if the room is unoccupied.
The system automatically saves energy by detecting whether or
not the room is occupied.
Based on preset user conditions, the system automatically stops
operation if the room is unoccupied.
Example
• Cooling setpoint: 26 • Shift temperature: 1.0
• Shift time:30 min. Limit cooling temperature:30
Example
• Heating setpoint: 2C Shift temperature: 1.0°C
• Shift time: 30 min. Limit heating temperature: 1C
20
19
18
Occupied Unoccupied
Automatically
reverts when
people return.
19℃
18℃
20℃20℃ 20℃20℃
19℃
18℃
Setpoint ()
Time
After 30 min After another 30 min
28
27
26
Occupied
Unoccupied
Automatically
reverts when
people return.
27℃
28℃
26℃26℃ 26℃26℃
27℃
28℃
Setpoint ()
Time
After 30 min After another 30 min
Absent stop time can be selected from 1 to 24 hrs in 1 hr increments
with remote controller.
Shift temperature and time can be selected from 0.5 to 4℃ in 0.5℃ increments and 15, 30, 45, 60, 90 or 120 minutes
respectively with remote controller.
Airflow block
air velocity
approx. 0.3m/s
*1
Airflow block function prevents uncomfortable drafts by reducing air velocity to
approx. 0.3m/s.*
2
The system automatically saves energy by detecting
whether or not the room is occupied. The set temperature
is shifted automatically if the room is unoccupied.
Airflow block function prevents uncomfortable drafts by
reducing air velocity.
It can be set using the BRC1E62 remote controller. There is no
need for sealing material of air discharge outlet (option).
This function only works when all-round flow is used. It cannot
be used when sealing material is used in the air discharge
outlet (option).
*1.These functions are not available when using the group control system.
*2.User can set these functions with remote controller.
*3.Please note that upon re-entering the room, air conditioner will not switch on automatically.
*1. Works in one direction only.
*2. In case of FXFQ63S type (Data is based on Daikin research.) When using FXFQ80S type or higher, if the airflow rate is set to High, airflow will be on the high side.
Under actual conditions, however, the airflow value may differ depending on the effect of surrounding conditions and the way in which the temperature was adjusted.
*3. A gap of 1500 mm is required if the air block function is not used.
Individual airflow setting
Airflow direction of each of the four air outlets can be controlled individually.
(
Positions 0 to 4, Swing, Blocked, and No individual setting are selectable.
)
Airflow block function*
1
Total comfort by individual airflow direction control and “airflow block function”
Sensing sensor low mode
(default: OFF)
When there are no people in a room, the set temperature
is shifted automatically.
Sensing sensor stop mode (default: OFF)
When there are no people in a room, the system stops automatically.*
3
1
2
3
4
Outlet mark
1
Blocked
3
Position 2
4
Swing
2
No individual
setting
(
Auto direction
)
Example
Swing
Position 2
blocked
No ind. set
A
Horizontal flow Airflow block
500mm
Wall
Airflow
block
*3
Also can support
such case
Airflow block
for cabinet side
The airflow block function
is useful when rearranging
the room layout.
Easy setup with remote controller
Sensing sensor mode*.
Individual airflow direction control
Ceiling Mounted Cassette (Round Flow with Sensing) Type
Operation is
reduced in places
where there are
no people.