Daikin RX36MY1 [86/255] Voltage characteristic of pressure sensor r410a

Daikin RX26MY1E [86/255] Voltage characteristic of pressure sensor r410a
Method of Troubleshooting SiE30-408
82 Troubleshooting
3. Voltage Characteristic of Pressure Sensor (R410A)
PH = 1.38V 0.69
P
L = 0.57V 0.28
P
H
: Detection pressure [High pressure side] MPa
P
L
: Detection pressure [Low pressure side] MPa
V
H
: Output voltage [High pressure side] V
DC
V
L
: Output voltage [Low pressure side] V
DC
Output voltage (VH, VL)
0
5.1 0.5
0
123 4
V
DC
10.2 1.0
15.3 1.5
30.6 3.0
25.5 2.5
20.4 2.0
(kg/cm
2
)MPa
(1.7MPa)
Detection pressure
P
H, PL
High pressure
(P
H)
Low pressure
(P
L)