Icom IC-R75 [22/48] Filter selection

Icom IC-R75 [22/48] Filter selection
18
5
RECEIVE FUNCTIONS
Filter selection
The filter selection switches the IF passband width
as shown in the table at right.
The filter selection is automatically memorized in
each mode.
q Select the desired mode with the mode s
witches.
w Push [FIL] one or more times to select the desired
filter combination.
ã or ç does not appear while in normal IF filter.
ç appears when wide IF filters are selected.
ã appears when narrow IF filters are selected.
When an optional filter is installed, set the optional
filter in filter set mode. Optional filters are not
selected by default.
• Filter construction
CFWS450E (15 kHz)
CFWS450HT (6 kHz)
FL-65 (2.4 kHz)
FL-257 (3.3 kHz)
FL-96 (2.8 kHz)
FL-222 (1.8 kHz)
FL-52A (500 Hz)
FL-53A (250 Hz)
optional
FL-23 (15 kHz)
FL-272 (2.4 kHz)
FL-103 (2.8 kHz)
FL-223 (1.9 kHz)
FL-100 (500 Hz)
FL-232 (350 Hz)
FL-101 (250 Hz)
optional
Mixer
2nd IF signal 3rd IF signal
9 MHz IF filter 455 kHz IF filter
IF Filter
Passband
width
Recommended
selectivity
9 MHz
FL-100 500 Hz/–6 dB CW-N, RTTY-N
FL-101 250 Hz/–6 dB
FL-103 2.8 kHz/–6 dB SSB-W
CW-N
FL-223 1.9 kHz/–6 dB SSB-N
455 kHz
FL-52A 500 Hz/–6 dB CW-N, RTTY-N
FL-53A 250 Hz/–6 dB CW-N
FL-96 2.8 kHz/–6 dB SSB-W
FL-232 350 Hz/–6 dB CW-N, RTTY-N
FL-222 1.8 kHz/–6 dB SSB-N
FL-257 3.3 kHz/–6 dB SSB-W

Содержание