Breadcrumb Field code Setting name Range, step
Default valu
e
Date Value
Field settings table
Installer setting at variance with
default value
A.8 [6-0D] R/W 0: Reheat only
1: Reheat + sched.
2: Scheduled onl
y
A.8 [6-0E] R/W 40~60°C, step: 1°C
60°C
A.8 [7-00]
0
A.8 [7-01]
2
A.8 [7-02] R/W
0: 1 LWT zone
1: 2 LWT zones
A.8 [7-03]
2.5
A.8 [7-04]
0
A.8 [7-05] R/W
0: Very high
1: High
2: Medium
3: Low
4: Ver
y
low
A.8 [8-00] R/W
0~20 min, step 1 min
1 min
A.8 [8-01] R/W 5~95 min, step: 5 min
30 min
A.8 [8-02] R/W 0~10 hour, step: 0,5 hour
0,5 hour
A.8 [8-03]
50
A.8 [8-04]
95
A.8 [8-05] R/W
0: No
1: Yes
A.8 [8-06] R/W 0~10°C, step: 1°C
5°C
A.8 [8-07] R/W [9-03]~[9-02], step: 1°C
18°C
A.8 [8-08] R/W [9-03]~[9-02], step: 1°C
20°C
A.8 [8-09] R/W [9-01]~[9-00]°C, step: 1°C
35°C
A.8 [8-0A] R/W [9-01]~[9-00]°C, step: 1°C
33°C
A.8 [8-0B]
13
A.8 [8-0C]
10
A.8 [8-0D]
16
A.8 [8-0E] R/W -15~25°C, step: 1°C
-7°C
A.8 [9-00] R/W 37~60°C, step: 1°C
55°C
A.8 [9-01] R/W 15~37°C, step: 1°C
25°C
A.8 [9-02] R/W 18~22°C, step: 1°C
22°C
A.8 [9-03] R/W 5~18°C, step: 1°C
5°C
A.8 [9-04] R/W 1~4°C, step: 1°C
1°C
A.8 [9-05] R/W 15~37°C, step: 1°C
25°C
A.8 [9-06] R/W
37~55, step: 1°C
55°C
A.8 [9-07] R/W 5~18°C, step: 1°C
5°C
A.8 [9-08] R/W 18~22°C, step: 1°C
22°C
A.8 [9-0C] R/W 1~6°C, step: 0,5°C
1 °C
A.8 [9-0D] R/W 0~8, step:1
0 : No limitation
1~4 : 50~80%
5~8 : 50~80% during sampling
6
A.8 [9-0E] R/W 0~8, step:1
0 : No limitation
1~4 : 50~80%
5~8 : 50~80% during sampling
6
A.8 [C-00]
0
A.8 [C-01]
0
A.8 [C-02] R/W
0: No
1: Bivalent
A.8 [C-03] R/W -25~25°C, step: 1°C
0°C
A.8 [C-04] R/W 2~10°C, step 1°C
3°C
A.8 [C-05] R/W 0: -
1: 1 contact
2: 2 contacts
A.8 [C-06] R/W 0: -
1: 1 contact
2: 2 contacts
A.8 [C-07] R/W
0: LWT control
1: Ext RT control
2: RT control
A.8 [C-08] R/W
0: No
1: Outdoor sensor
2: Room sensor
A.8 [C-09] R/W
0: Normally open
1: Normall
y
closed
A.8 [C-0A]
0
A.8 [C-0C]
0
A.8 [C-0D]
0
A.8 [C-0E]
0
A.8 [D-00] R/W
0: None
1: -
2: BUH only
3: -
What is the required alarm output contact type?
--
--
--
--
Which heaters are permitted if prefer. kWh rate PS is cut?
Bivalent activation temperature.
Bivalent hysteresis temperature.
What is the thermo request contact type for the main zone?
What is the thermo request contact type for the add. zone?
What is the unit control method in space operation?
Which type of external sensor is installed?
Room temperature hysteresis.
Pump speed limitation
Pump speed limitation additional Zone
--
--
Is an external backup heat source connected?
What is the mimimum desired LWT for main zone in cooling?
Leaving water temperature overshoot temperature.
What is the mimimum desired LWT for add. zone in heating?
What is the maximum desired LWT for add. zone in heating?
What is the mimimum desired LWT for add. zone in cooling?
What is the maximum desired LWT for add. zone in cooling?
--
--
What is the ambient temp for BUH only operation?
What is the maximum desired LWT for main zone in heating?
What is the mimimum desired LWT for main zone in heating?
What is the maximum desired LWT for main zone in cooling?
Leaving water temperature maximum modulation.
What is the desired comfort main LWT in cooling?
What is the desired eco main LWT in cooling?
What is the desired comfort main LWT in heating?
What is the desired eco main LWT in heating?
--
Minimum running time for domestic hot water operation.
Maximum running time for domestic hot water operation.
Anti-recycling time.
--
--
Allow modulation of the LWT to control the room temp?
--
--
How many leaving water temperature zones are there?
--
--
Boiler efficiency
What is the desired DHW production type?
What is the maximum temperature setpoint?