5 | Application guidelines
Installer reference guide
31
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1A – 2020.05
Heatpump convectors – Multiple rooms
Setup
A
B C
a a
A Main leaving water temperature zone
B Room 1
C Room 2
a Remote controller of the heat pump convectors
For more information about connecting the electrical wiring to the unit, see:
- "8.2Connections to the outdoor unit"[489]
- "8.3Connections to the indoor unit"[490]
The desired room temperature is set via the controller of the heat pump
convectors. There are different controllers and setups possible for the heat pump
convectors. For more information, see:
- The installation manual of the heat pump convectors
- The installation manual of the heat pump convector options
- The addendum book for optional equipment
The user interface connected to the indoor unit decides the space operation
mode.
The heating or cooling demand signals of each heat pump convector are
connected in parallel to the digital input on the indoor unit (X2M/35 and
X2M/30). The indoor unit will only supply leaving water temperature when there
is an actual demand.
INFORMATION
To increase comfort and performance, we recommend to install the valve kit option
EKVKHPC on each heatpump convector.
Configuration
Setting Value
Unit temperature control:
#: [A.2.1.7]
Code: [C-07]
1 (Ext RT control): Unit operation
is decided by the external thermostat.
Benefits
Compared with heatpump convectors for one room:
Comfort. You can set the desired room temperature, including schedules, for
each room via the remote controller of the heatpump convectors.