Daikin FTKE25BVMT [85/268] Super multi nx b series heat pump

Daikin FTKE25BVMT [85/268] Super multi nx b series heat pump
Specifications ED12-321A
80 SUPER MULTI NX B-Series Heat Pump
Cooling [240V]
Heating [240V]
Notes:
1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature), 35°CDB (Outdoor temperature).
Heating capacity is based on 20°CDB (Indoor temperature), 7°CDB/6°CWB (Outdoor temperature).
2. The total ability of connected indoor units is up to 11.0kW.
3. It is impossible to connect the indoor unit for one room only.
3D039671#2
3D039671#3
50Hz
Combination of
Indoor Unit
Each Capacity (kW) Total Capacity (kW) Total Input (W) Total Current (A)
Power
Factor (%)
A room B room C room D room Rating (min~max) Rating (min~max) Rating (min~max) Rating
2.5 2.50 ———2.50 1.58~3.02 830 440~1150 3.6 1.9~5.0 96
3.5 3.50 ———3.50 1.67~3.92 1250 460~1530 5.3 2.0~6.5 98
5.0 5.00 ———5.00 1.75~5.22 1810 530~1920 7.6 2.2~8.1 99
6.0 ——6.00 6.00 1.88~6.16 2700 560~2970 11.4 2.4~12.5 99
2.5+2.5 2.50 2.50 ——5.00 1.75~5.31 1710 470~1940 7.2 2.0~8.2 99
2.5+3.5 2.42 3.38 ——5.80 1.88~6.24 2290 500~2720 9.6 2.1~11.4 99
2.5+5.0 2.08 4.16 ——6.24 2.09~6.64 2090 560~2380 8.8 2.4~10.0 99
2.5+6.0 1.88 4.52 6.40 2.24~6.78 2220 600~2520 9.3 2.5~10.6 99
3.5+3.5 3.00 3.00 ——6.00 2.01~6.45 2430 530~2720 10.2 2.2~11.4 99
3.5+5.0 2.64 3.76 ——6.40 2.24~6.78 2260 610~2560 9.5 2.6~10.8 99
3.5+6.0 2.42 4.14 6.56 2.40~7.05 2390 640~2760 10.1 2.7~11.6 99
5.0+5.0 3.32 3.32 ——6.64 2.47~7.21 2100 610~2380 8.8 2.6~10.0 99
5.0+6.0 3.09 3.71 6.80 2.63~7.27 2190 640~2380 9.2 2.7~10.0 99
2.5+2.5+2.5 2.08 2.08 2.08 6.24 2.09~6.94 1860 530~2360 7.8 2.2~9.9 99
2.5+2.5+3.5 1.88 1.88 2.64 6.40 2.24~6.99 1980 570~2410 8.3 2.4~10.1 99
2.5+2.5+5.0 1.66 1.66 3.32 6.64 2.47~7.26 1940 580~2360 8.2 2.4~9.9 99
2.5+2.5+6.0 1.55 1.55 3.70 6.80 2.63~7.41 2110 620~2610 8.9 2.6~11.0 99
2.5+3.5+3.5 1.78 2.51 2.51 6.80 2.40~7.23 2170 610~2680 9.1 2.6~11.3 99
2.5+3.5+5.0 1.55 2.16 3.09 6.80 2.63~7.41 2110 620~2610 8.9 2.6~11.0 99
3.5+3.5+3.5 2.26 2.26 2.26 6.78 2.55~7.38 2150 660~2780 9.0 2.8~11.7 99
50Hz
Combination of
Indoor Unit
Each Capacity (kW) Total Capacity (kW) Total Input (W) Total Current (A)
Power
Factor (%)
A room B room C room D room Rating (min~max) Rating (min~max) Rating (min~max) Rating
2.5 3.86 ———3.86 1.46~4.75 1340 480~1730 5.7 2.0~7.4 98
3.5 4.42 ———4.42 1.61~5.40 1630 540~2130 6.9 2.3~9.0 99
5.0 6.13 ———6.13 1.84~7.40 2050 460~2820 8.6 1.9~11.9 99
6.0 ——7.32 7.32 2.00~8.35 2650 480~3320 11.2 2.0~14.0 99
2.5+2.5 3.55 3.55 ——7.10 2.14~7.95 2340 520~3030 9.8 2.2~12.8 99
2.5+3.5 3.18 4.45 ——7.63 2.26~8.40 2610 550~3330 11.0 2.3~14.0 99
2.5+5.0 2.83 5.67 ——8.50 2.44~8.87 2830 540~3060 11.9 2.3~12.9 99
2.5+6.0 2.53 6.07 8.60 2.55~9.15 2840 560~3110 12.0 2.4~13.1 99
3.5+3.5 4.00 4.00 ——8.00 2.38~8.55 2830 570~3240 11.9 2.4~13.6 99
3.5+5.0 3.54 5.06 ——8.60 2.55~9.15 2870 560~3150 12.1 2.4~13.3 99
3.5+6.0 3.17 5.43 8.60 2.68~9.25 2790 580~3130 11.7 2.4~13.2 99
5.0+5.0 4.30 4.30 ——8.60 2.74~9.45 2460 550~2880 10.4 2.3~12.1 99
5.0+6.0 3.91 4.69 8.60 2.86~9.55 2400 570~2870 10.1 2.4~12.1 99
2.5+2.5+2.5 2.86 2.86 2.86 8.58 2.80~9.40 2760 620~3170 11.6 2.6~13.3 99
2.5+2.5+3.5 2.53 2.53 3.54 8.60 2.95~9.41 2610 650~3170 11.0 2.7~13.3 99
2.5+2.5+5.0 2.15 2.15 4.30 8.60 3.18~9.55 2430 640~2850 10.2 2.7~12.0 99
2.5+2.5+6.0 1.95 1.95 4.70 8.60 3.33~9.60 2410 670~2820 10.1 2.8~11.9 99
2.5+3.5+3.5 2.26 3.17 3.17 8.60 3.10~9.45 2520 680~3170 10.6 2.9~13.3 99
2.5+3.5+5.0 1.95 2.74 3.91 8.60 3.33~9.60 2380 670~2860 10.0 2.8~12.0 99
3.5+3.5+3.5 2.86 2.86 2.86 8.58 3.25~9.55 2410 730~3070 10.1 3.1~12.9 99

Содержание

Скачать